Pulse Trigger Source: This
can only come from J-panel.
Figure 30. I/O board settings (no access to I/O Board settings)
5.1 Power requirements – Drive5 system
The Drive5 system requires a 24V DC power supply. The table below shows the power consumption
for two Drive5 units connected to a power supply via the recommended J-Panel board (4.2 * 24 =
100.8 W, steady state). For direct connection of a single unit to a 24V DC power supply, inrush
current is 3.5 A, steady state current is 2.0 A.
System Components
Drive5 System #0 (with heater on)
Drive5 System #1 (with heater on)
J-Panel (VJP-300)
Total
* When connected using J-Panel, inrush current is limited to 6.5 A
Table 3
Drive5 power requirements
Light: Nighttime lighting can
come from TNL-50 (select
Flash).
Current (Steady State)
2.0 A
2.0 A
0.2 A
4.2 A
― 34 ―
Source/Type: Communication to
various external devices. For TNL-
50, use RS-485. For Laser, use
RS-232. Default is RS-485.
Response: Select between Normal
and Interrupt. Interrupt is only for
factory use. Default is Normal.
Flash Status Type: TNF DC or
TNF AC. For TNL-50 use DC
option.
Flash Strobe: Enable or Disable
function. Default is Enabled.
Current (Inrush)
3.5 A
3.5 A
1.5 A
6.5 A*