Precautions for maintenance and inspection
7.6.7

Replacement of parts

The inverter consists of many electronic parts such as semiconductor devices.
The following parts may deteriorate with age because of their structures or physical
characteristics, leading to reduced performance or fault of the inverter. For preventive
maintenance, the parts must be replaced periodically.
Part Name
Cooling fan
Main circuit smoothing
capacitor
On-board smoothing
capacitor
Relays
CAUTION
For parts replacement, consult the nearest Mitsubishi FA Center.
Standard Replacement
Interval
2 to 3 years
10 years
10 years
_
56
Description
Replace (as required)
Replace (as required)
Replace the board (as required)
Replace as required