7.2 To know the operating status at the occurrence of alarm
(only when FR-PU04 is used)
When any alarm has occurred, the display automatically switches to the indication of the
corresponding protective function (error). By pressing the
resetting the inverter, the display shows the output frequency. In this way, it is possible to
know the running frequency at the occurrence of the alarm. It is also possible to know the
current in the same manner. After resetting, you can confirm the definitions in "Alarm
History". (For details, refer to the instruction manual of the parameter unit (FR-PU04).)

7.3 Correspondence between digital and actual characters

There are the following correspondences between the actual alphanumeric characters
and the digital characters displayed on the operation panel:
Actual
Display
0
1
2
3
4
5
6
7
8
9

7.4 Resetting the inverter

Performing any of the following operations resets the inverter. Note that performing a
reset clears (erases) the internal thermal integrated value of the electronic thermal
relay function and the number of retries.
Recover about 1s after reset is cancelled.
(Err) flickers on the operation panel during reset.
Operation 1 ....... Using the operation panel, perform a reset with the
(Enabled only when the inverter protective function is activated
(major failure))
Operation 2........ Cut (off) power once, then switch it on again.
Operation 3 ....... Turn on the reset signal (RES). (Assign this signal to any of Pr. 60 to
Pr. 63.) (Refer to page 35.)
To know the operating status at the occurrence of alarm
Actual
Display
A
B
C
D
E
F
G
H
I
J
L
47
(only when FR-PU04 is used)
MON
at this point without
Actual
Display
M
N
O
o
P
S
T
U
V
r
-
STOP
.
RESET
7

Advertisement

Table of Contents
loading

Table of Contents