Chapter 4 — Troubleshooting and Maintaining the Printer
RFID Problems and Possible Solutions (continued)
Problem
When I send a TAGREAD or
TAGWRITE command, I get this
error message: "Tag format error."
Data can be written unlawfully to a
write protected ISO 18000-6B tag.
I can read ISO 18000-6B tags, but
when I try to read Class 1 tags, I get
this error message: "No tag found."
(Fingerprint only) My printer
displays an error code.

Resetting the Printer

104
Possible Solution
The TAGFORMAT defined for the operation determines
the number of required parameters. You may need to
modify the TAGFORMAT. For help, see the
Fingerprint Command Reference Manual
Command Reference
EPC Tag Data Standard (v1.1, revision 1.27) available from
the EPCglobal website at
For some ISO 18000-6B tag chips, the functionality to
protect the tag memory from being rewritten has not been
implemented. Switch to tags with a different chip that have
this functionality implemented.
Class 1 tags require an MPR6100 RFID Radio Module. To
order an MPR6100 kit, contact your local Intermec
representative.
Use the error code text to troubleshoot the problem:
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
Note: If you are using Intermec Direct Protocol, error codes
1320 to 1329 are supported and displayed with the error
text.
When you reset the printer, you return it to the factory default
settings. Resetting the printer removes all files used to store settings.
But, it does not reset settings that have already been read when the
files. So, wireless communication settings, such as SSID and keys
retain their values from the previous start. However, the next reboot
resets them to the factory default values.
Manual. For more information, see the
www.epcglobalinc.org.
No RFID support installed.
No tag found.
Access outside tag memory.
Tag format error.
RFID inactive.
Not supported by tag type.
RFID module too hot.
RFID duty cycle exceeded.
RFID lock error. Tag cannot be locked.
RFID access error. Tag is locked.