Sub-Zero 424 Installation Manual page 17

Hide thumbs Also See for 424:
Table of Contents

Advertisement

Models 427 and 427R Installation
Models 427 and 427R Installation
Refer to the previous page for overall dimensions and
door swing clearances for models 427 and 427R.
Make sure that the finished rough opening where the wine
storage unit is to be installed is properly prepared. Refer
to the illustration for rough opening dimensions for models
427 and 427R. The floor under the unit must be level with
the surrounding finished floor.
IMPORTANT NOTE: To operate properly, the door must
open a minimum of 90°. Use a minimum 2" (51) filler in
corner installations to assure a 90° door opening. Allow
enough clearance in front of the unit for full door swing.
Do not load wine into the wine storage unit until the
installation is complete.
OPENING DIMENSIONS
25"
(635)
OPENING DEPTH
SIDE VIEW
IMPORTANT NOTE: The depth of each integrated model is
24" (610) from the front of the unit to its back. Your design
may necessitate moving the unit back or cabinets forward to
achieve a flush fit. This will require a minimum rough opening
depth of 25" (635).
subzero.com
TOP VIEW
25"
(635)
OPENING
DEPTH
80"
27"
(2032)
(686)
OPENING
OPENING WIDTH
HEIGHT
FRONT VIEW