Sub-Zero 424 Installation Manual page 18

Hide thumbs Also See for 424:
Table of Contents

Advertisement

Models 427 and 427R Installation
Electrical Requirements
For models 427 and 427R, the electrical supply should be
located within the shaded area shown in the illustration.
Follow the National Electrical Code and local codes and
ordinances when installing the receptacle. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and
may cause interruption of operation.
IMPORTANT NOTE: For models 427 and 427R, the elec-
trical outlet must be placed so the grounding prong is to
the right of the thinner blades. The outlet must be flush
with the back wall.
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity and is
properly grounded.
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance. Do not
remove the power cord ground prong.
Electrical Requirements
Power Supply
Circuit Breaker
Receptacle
LEFT SIDE
OF OPENING
1
2
/
"
2
(64)
13"
(330)
1
4
/
2
( 114 )
1
FLOOR
/
"
4
(6)
FRONT VIEW
Location of electrical supply.
115 V AC, 60 Hz
3-prong grounding-type
"
18
15 amp