Model WS-30 Installation
Position the Unit
Use an appliance dolly to move the unit near the rough
opening. Model WS-30 is equipped with rollers, so it can
be moved into position more easily.
Shut off power to the electrical outlet. Plug the power cord
into the 15 amp grounded outlet and roll the unit into
position. Be sure that the anti-tip brackets are properly
engaged.
IMPORTANT NOTE: If possible, keep the door closed until
the unit is properly anchored.
IMPORTANT NOTE: If for any reason the unit has been laid
on its back or side, you must allow the unit to stand
upright for a minimum of 24 hours before connecting
power.
Protect any finished flooring before moving the unit
into place
To reduce the possibility of the unit tipping forward, the
front leveling legs must be in contact with the floor once
the unit is in position.
Level the Unit
Once the unit is in position, extend the front leveling legs
down by turning the legs clockwise to adjust the height.
The rear height adjustment can be made from the front of
3
the base. Use a
/
" socket to adjust the rear rollers. Turn
8
3
the
/
" hex bolt clockwise to raise the unit or counter-
8
clockwise to lower it. Refer to the illustration below for
location of the rear roller base adjustment.
IMPORTANT NOTE: Be sure to reference leveling of the
unit to the floor and not to surrounding cabinetry. This
could affect the operation of the unit, such as door
closing.
FRONT
LEVELING LEG
REAR
ADJUSTMENT
Rear roller base adjustment.