Checks
A periodic check of the pilot and
burner flames should be made.
Check after the fire has been on
for at least 30 minutes. The pilot
flame must cover the tip of the
thermocouple probe. The main
burner flame pattern will vary from
appliance to appliance depending
on the type of installation and
climatic conditions.
The appliance area must always
be kept clear and free from
combustible materials, gasoline and other flammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make sure that dirt, snow, insects, leaves, shrubs, trees do not
obstruct it.
Examine the whole vent system regularly. We recommend annually.
Batteries
All appliances use four 1.5V AA batteries for remote control receivers and the handset uses a 9V battery.
Batteries are accessible by opening the bottom access panel and removing the lid of the remote control receiver.
Batteries should last one to two seasons, depending on usage. Removing batteries in the off season will extend
battery life.
Servicing
If your appliance require any attention, contact your supplier quoting the model number. It will be helpful if the
appliance serial number can also be quoted. This is on the rating plate, which is on a chained, plate accessible by
opening the bottom access panel.
The repair parts are shown in the separate repair parts leaflet. Please always quote part number and description
when requesting spare parts.

Remote Control Operation

NOTE: Before using the remote control system for the first time, the receiver and the handset must be
synchronized. See the section Initial Remote Control Set-up on page 24 in this manual.
Your fireplace remote control helps you get the comfort, convenience and aesthetics you want from your gas fireplace.
The remote controls your fireplace in different ways.
IMPORTANT: BEFORE YOU BEGIN, please note that on this system, the settings of time, temperature and automatic
ON/OFF can only be programmed when the function display is flashing. Be patient when programming as it can take
a few seconds to set.
Turning your fireplace ON
1.
Make sure that the MAN knob on the valve is in ON position.
.
Make sure that the switch on the valve is in the I position.
.
Press and hold the OFF and
Release the buttons.
The acoustic signals will continue until the pilot lights. The remote control will go automatically
into TEMP mode. The flame will be at maximum height until the remote control reads the
temperature (factory set) and will then adjust the flame accordingly.
You can put the remote in MAN manual mode, change the temperature in TEMP mode or
program your remote in TIMER mode as indicated in the following sections.


Owner's Information
Thermocouple
probe must be
in flame
WARNING: When the pilot is lit, the valve motor
turns automatically to maximum flame height.
(large flame) buttons until you hear a short acoustic signal.
Correct flame appearance
With Logs