Operating the Fire

MANUAL CONTROLS

The manual controls are located at the base of the appliance. The manual controls consist of a main switch and a
thermostat (Fig. 9a). Remove the ash pan to access the controls. The main switch controls the electricity supply to the
appliance.The switch can be pressed on either side. Please see the table below for the functions that correspond to the
switching sequence.
Switch Operation
Press
Once
Press
Press
Press
Press
Once
Two Red LED's as shown in Fig. 9b are located behind the flame panel and indicate the heat setting of the appliance.
These LED's illuminate when a heat setting is selected and remain illuminated for aproximatly 3 seconds.
- One illuminated LED corresponds to Half Heat - 650 Watts
- Two illuminated LED's correspond to Full Heat - 1300 Watts
SETTING THE THERMOSTAT
While either half or full heat is activated, turn the thermostat knob to MAX to warm the room rapidly. When the room
temperature has reached the desired level, turn the thermostat knob back slowly until the thermostat clicks off. The
heater will then maintain the room temperature at the chosen level.
Note: Should your heater fail to come on when the thermostat is at a low setting, this may be due to the room temperature
being higher than the thermostat setting.

REMOTE CONTROL OPERATION

The two buttons on the remote control operate in the same way as the manual switch located at the base of the
appliance. Operation of the remote control buttons corresponds to the switching sequence in the above table.
Please note that it takes time for the receiver to respond to the remote control. Do not press the buttons more than once
within two seconds for correct operation.

BATTERY INFORMATION

1. Unclip the battery cover on the back of the remote control. (Fig. 10)
2. Install AAA batteries into the remote control, making sure to orient the positive and negative terminals correctly.
3. Replace the battery cover.
DiscardIing leaky batteries
Dispose of batteries in the proper manner according to national and local regulations. Any battery may leak electrolyte if
mixed with a different battery type, if inserted incorrectly, if all the batteries are not replaced at the same time, if disposed
of in a fire, or if an attempt is made to charge a battery not intended to be recharged.

THERMAL SAFETY CUT-OUT

A thermal safety cut-out is incorporated in the fan heater to prevent damage due to overheating. This can happen if the
heat outlet is restricted in any way or if the chimney flue has not been blocked off effectively. The cut-out operates by
cutting the power to the fan heater if the heater overheats. To restore power to the fan heater, unplug the appliance and
leave it rest for approximately 30 minutes. Once the temperature in the fan heater has reduced, plug the appliance in
and power it back on. If the fan heater cuts out during operation, remove any obstruction that may be restricting the heat
outlet before carrying out the above steps.
LED Hologram Effect On
LED Hologram & Flame Effect On
Once
Flame Effect & Half Heat On
Again
Flame Effect & Full Heat On
Again
Setting
Fire is turned off
Visual Indication
Flame panel illuminated
Flame movement within flame panel
1 Red LED behind flame panel
2 Red LED's behind flame panel
Flame panel becomes darkened