Specifications - Valor Portrait 530ILN/ILP Installation & Operating Instructions Manual

Direct vent gas fireplace heater
Hide thumbs Also See for Portrait 530ILN/ILP:
Table of Contents

Advertisement

Approvals and Codes
This appliance is certified to ANSI Z21.88b–2008/CSA 2.33b–2008 Vented Gas Fireplace Heater Standard for use in
Canada and USA.
The appliance complies with CGA P.4.1, Testing method for measuring annual fireplace efficiencies.
The installation must conform with local codes or, in the absence of local codes with the National Fuel Gas Code,
ANSI Z223.1or the Natural Gas and Propane Installation Code CAN/CGA-B149. Only qualified licensed or trained
personnel should install the appliance.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C.1.
Ratings
Altitude (Ft)
Input Max. (Btu/h)
Input Min (Btu/h)
Manifold pressure (in.w.c.)
Min. Supply pressure (in. w.c.)
Max. Supply pressure (in. w.c.)
*Tested to CAN/CGA - 2.17 Gas fired appliances for use at high altitudes. In USA, installations may require deration
over 000'—Check local codes.
Front Trims
Various fronts are available for the 530I engine. This engine may be installed as a free standing, zero clearance or
insert application depending on which style front trim is selected. The front trim style affects the framing cavity,
clearances and position of the engine. A front trim kit is required for all applications and should be on site
when the engine is installed as the parts to make the engine suitable for zero clearance are supplied with the front
trim kits (except 549 front).
Fuel Beds
The 530I engine is available in either natural gas or propane gas and comes equipped with either a simulated log or
coal fuel bed in either fuel.
Venting options
The 530I engine unit is supplied standard with a rear direct vent outlet and may be converted to a top direct vent
outlet with no extra parts required—see Conversion to Top Outlet for Solid Direct Vent Co-axial Piping in the
Appliance Preparation section further on in this manual.
Direct vent installations (solid piping)
A list of all approved venting accessories is shown on pages 32–33 of this manual.
Direct Vent Co-Linear Installations for Free Standing or Recessed Installations (flexible piping)
Converts the appliance outlet collars to accept two 3" dia. flexible liners for installation into existing solid-fuel burning
fireplaces and chimneys. Requires a co-linear adapter at the appliance and either a co-linear terminal or co-linear-
to-co-axial terminal at the top of the chimney. A list of approved venting accessories is shown on pages 32–33 of this
manual.

Specifications

NG
LPG
0-00 *
0,00
19,000
,000
11,00
3.5 – 3.9
10.3 – 10.7

11
10.
1
 