Maintaining The Sabre 1552 Laser Scanner - Intermec Sabre 1552 User Manual

Hide thumbs Also See for Sabre 1552:
Table of Contents

Advertisement

c o d e 39
Troubleshooting (continued)
Symptom
Solution
The battery pack power is low. Remove the
The yellow LED
battery pack and charge it. For help, see the
flashes when you
Sabre Battery Pack Instruction Sheet (Part
pull the trigger.
No. 067673-001).
Scanner emits a
The scanner is out of range of the base
continuous beep.
station. Move the scanner and base station to
within 50 feet (15 meters) of each other.
Scanner does not
The scanner is not receiving power. Make
emit a beam and
sure the battery pack is fully charged. Replace
does not operate.
the battery pack if damaged.
If you continue to encounter problems with your scanner,
contact your local Intermec representative.

Maintaining the Sabre 1552 Laser Scanner

Water or grime on the window of the scanner will distort the
laser beam and impair performance. Moving from one
temperature extreme to another causes condensation to form on
the optical surfaces that affects scanner performance.
Clean the window with a cotton cloth moistened with an
ammonia or water solution. Dry with a soft cotton cloth or
allow to air dry.
Do not use a dry tissue to wipe the window. This causes
small scratches on the window that will gradually affect
performance.
Do not immerse the unit in water.
Operate and store the scanner and battery pack in an
environment with 0% to 95% relative humidity.
Operate the scanner in temperatures within -4°F to 122°F
(-20°C to 50°C) and store the scanner in temperatures within
-22°F to 140°F (-30°C to 60°C).
Operate the battery pack in temperatures within -4°F to
122°F (-20°C to 50°C) and store the battery pack in
temperatures within -22°F to 140°F (-30°C to 60°C).
15