Design and installation of
venting systems should be
done only be qualified and
knowledgeable venting systems
personnel and in accordance
with vent system
manufacturer's installation
instructions. Installing a boiler
or vent system using improper
installation methods or
materials can result in serious
injury or death due to fire or
asphyxiation.
Before connecting a boiler to a
venting system, it must be
determined whether the boiler
is to be installed in a
conventional or direct vent
configuration. In the US,
provisions for combustion air
must be in accordance with
NFPA 54/ANSI Z223.1, National
Fuel Gas Code, latest edition,
or applicable provisions of
local building codes. In
Canada, combustion and
ventilation air openings shall
comply with CAN/CSA B-149.1
Natural Gas and Propane
Installation Code.
For correct installation of vent
system, read all of these
instructions and refer to vent
manufacturer's instructions.
Failure to use a proper vent
system (types and materials),
as described in this manual will
void the boiler warranty and
may result in rapid deterioration
of the venting system, creating
a health or life safety hazard.
Faulty vent installation can
allow toxic fumes to be
released into living areas. This
may cause property damage,
injury or death.

2.4 Inlet Air and Exhaust Venting Considerations

2.4.1 Applicable Codes and Standards

United States:
NFPA 54/ANSI Z223.1
NFPA/ANSI 211
Canada:
CAN/CSA B149.1
Standards:
UL 1738
ULC S636-95
These codes and standards contain information for the venting of gas
fired appliances, including, but not limited to vent sizing, location,
clearance to combustibles, and safe installation practices. The installation
must comply with both the above Federal Codes and with state, provincial
and local codes.
This table is for information only. Combustion air dampers
and vent adapters are listed for use of design and may or
may not be specific to your application.
Required Stainless Steel Vent Adapters and Category II Motorized Dampers
Boiler Size Nom. vent
Stainless
Size
Vent Adapter
SC-1500
10"
2640000133
SC-2000
10"
2640000133
SC-3000
10"
2640000133
SC-4000
10"
2640000133
P-K SONIC
T T T T echnical Service 1.877.728.5351
echnical Service 1.877.728.5351
echnical Service 1.877.728.5351
echnical Service 1.877.728.5351
National Fuel Gas Code
Chimneys, Fireplaces, Vents and Solid Fuel Burning
Appliances
Installation Codes for Gas Burning Equipment
Venting Systems for Gas-Burning Appliances,
Categories II, III and IV
Standard for Type BH Venting System
Sheet Metal and Thermoplastic Duct Construction
Manual Air Conditioning Contractors National
Association (SMACNA)
NOTE
Boiler Vent and Adapter Sizes
Vent
Boiler
adapter
Combustion
size
Air inlet
10"
10"
10"
10"
TM
Gas Fired Boiler
Combustion air
N.C. Motorized
Damper
12"
1004906946
12"
1004906946
12"
1004906946
12"
1004906989
Size
12"
12"
12"
14"