Initialization; System Configuration Change - NEC S1500 Setup Manual

Disk array unit
Hide thumbs Also See for S1500:
Table of Contents

Advertisement

5.2

Initialization

Your system was initialized at the factory. We recommend you only make changes to the system
configuration, and do not perform the initialization process at your side.
5.3

System Configuration Change

The configuration of the disk array unit can be changed according to the procedures described below
when it is required due to a system change or for some other reason. The network configuration and
license unlocking are enabled by the WebSAM NEC Storage Manager.
To change from the disk array controller of the single controller model to that of the dual controller
model, first confirm that Controller 1 is activated normally (the DIR LED blinks regularly) and then
start the Setup Wizard to provide [Host port configuration] and [Network configuration] in [System
configuration change or Addition]
Start dialog
Selection
Configuration
Host Port
Configuration
Disk Enclosure Unit
Configuration
Confirms that
the Disk Enclosure
Network
configuration
Confirmation and
adaptation of
configuration
Configuration
Completed
Confirm that the target disk array unit is correct.
See "5.3 (1) Start dialog" for details.
Select the configuration change mode and specify the terms that
require changing. See "5.3 (2) Selection".
Confirm that the settings preparation is completed.
See "5.3 (3) Configuration" for details.
Set the port connection platform and FC port information.
See "5.3 (4) Host Port configuration" for details.
Set the FC and/or SATA disk enclosure information.
See "5.3 (5) Disk Enclosure Unit Configuration" for details.
Confirm the connection of the FC and/or SATA disk enclosure.
See "5.3 (6) Confirmation that the Disk Enclosure" for details.
Set the disk array unit network information.
See "5.3 (7) Network configuration" for details.
Confirm that the settings contents are correct and upload the
configuration. See "5.3 (8) Confirmation of configuration" and "5.3 (9)
Uploading the configuration" for details.
Confirm that the configuration is correct.
See "5.3 (10) Configuration completed" for details.
If the configuration fails, check the status of the disk array unit.
See "5.3 (11) Failure in configuration" for details.
-