Water Valves; Recirculating Valve - Fisher & Paykel WA37T26EW Service Manual

Ecosmart electronic washer
Table of Contents

Advertisement

479602
To enter the option adjustment mode:
1. Plug the machine in but do not press POWER.
2. Press and hold the Start / Pause button, then press the Power button
3. Three quick beeps will be heard and the machine will show an unusual pattern of lights.
4. Carry out any option adjustments necessary.
Refer to the Use & Care manual for the various options adjustments available
5. Press POWER to return to normal mode.
3.5

Water Valves

The machine uses a dual valve block assembly.
Independent coils control the hot and cold water
supply, which feeds the water through a
common outlet.
The valve block has a location feature for the
thermistor.
3.6

Recirculating Valve

The Recirculating Valve is situated at the
bottom of the Tub beside the Pump. It consist of
a wax solenoid which heats up and moves a
flapper to close off the drain enabling the water
to be recirculated back into the inner basket,
with the pump running. When powered on there
is 160 volts DC across the terminals.
NB: The Valve takes approximately 1 minute
to activate and 3 minutes to cool down and
return to its normal position.
Drain Hose
Drain Pump Hose
Recirculating Hose