Note: See "System" on page 116 to determine which components should be replaced by a field service technician.
Error code/symptom
1962
(Drive does not contain a valid boot
sector)
2400
(Video controller test failure)
2462
(Video memory configuration error)
5962
(IDE CD-ROM drive configuration error)
8603
(Pointing-device error)
0001200
(Machine check architecture error)
00012000
(Microprocessor machine check)
00019501
(Microprocessor 1 is not functioning -
check VRM and microprocessor LEDs)
00019502
(Microprocessor 2 is not functioning -
check VRM and microprocessor LEDs)
00019701
(Microprocessor 1 failed)
00019702
(Microprocessor 2 failed)
00180100
(A PCI adapter has requested memory
resources that are not available.)
FRU/action
1. Verify that a startable operating system is installed.
2. Run diagnostics.
3. Hard disk drive.
4. SCSI backplane.
5. Cable.
6. System board.
1. Video adapter (if installed)
2. System board
1. Video adapter (if installed)
2. System board
1. Run the Configuration/Setup Utility program.
2. CD-ROM drive.
3. CD-ROM power cable.
4. IDE cable.
5. System board.
6. Battery.
1. Pointing device
2. System board
1. Microprocessor 1
2. Optional microprocessor 2
1. Microprocessor
2. System board
1. VRM 1
2. Microprocessor 1
3. System board
1. VRM 2
2. Microprocessor 2
1. Microprocessor 1
2. System board
1. Microprocessor 2
2. System board
1. Reorder the adapters in the PCI slots. It is important that your
startup device is positioned early in the startup-device order so
that it is run by POST.
2. Ensure that the PCI adapter and all other adapters are set correctly
in the Configuration/Setup Utility program Utility program. If the
memory resource settings are not correct, change the settings.
3. If all memory resources are being used, you might need to remove
an adapter to make memory available to the PCI adapter. Disabling
the adapter BIOS on the adapter might correct the error. (See the
documentation provided with the adapter.)
Chapter 6. Symptom-to-FRU index