Note: See "System" on page 116 to determine which components should be replaced by a field service technician.
Error code/symptom
1304
2
(I
C cable to diagnostic LED board not
found)
1600
(The system management processor is not
functioning) Complete the following steps
before replacing a FRU:
1. Ensure that a jumper is not installed
on J34.
2. Remove the ac power to the server,
wait 20 seconds; then, reconnect the
ac power. Wait 30 seconds; then, turn
on the server.
1601
(The system is able to communicate to the
system management processor, but the
system management processor failed to
respond at the start of POST.) Complete
the following steps before replacing a
FRU:
1. Remove the ac power to the server,
wait 20 seconds; then, reconnect the
ac power. Wait 30 seconds; then, turn
on the server.
2. Flash update the system management
processor.
1602
(Cable for optional service processor
adapter not installed)
1762
(Hard disk configuration error)
178X
(Fixed disk error)
1800
(No more hardware interrupt available for
PCI adapter)
104
xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Power switch assembly
2. System board
v System board
1. Remote Supervisor Adapter, if installed
2. System board
v Disconnect all server and option power cords from server, wait
30 seconds, reconnect, and retry.
1. Hard disk drive.
2. Hard disk cables.
3. Run the Configuration/Setup Utility program.
4. Hard disk adapter.
5. SCSI backplane.
6. System board.
1. Hard disk cables.
2. Run diagnostics.
3. Hard disk adapter.
4. Hard disk drive.
5. System board.
1. Run the Configuration/Setup Utility program.
2. Failing adapter.
3. System board.