Attaching The Cable Retention Arm - NEC EXPRESS5800/140Hb Service Manual

Hide thumbs Also See for EXPRESS5800/140Hb:
Table of Contents

Advertisement

Attaching the Cable Retention Arm

The dual-hinged cable retention arm attaches to the rear of the server and allows
cables to swing in and out of the way as the server slides back and forth within
the rack cabinet. All the server cables can be tie-wrapped to the cable retention
arm.
Note:
first slide the server into the rack cabinet and then install the
cable retention arm.
1. Using two screws attach one end of the cable retention arm to the rear of the
server (see Figure 2-9).
2. Using two screws attach the other end of the cable retention arm to the cage
nuts installed in the left rear vertical mounting rail (see Figure 2-9).
3. Bundle all the server cables together and tie-wrap them to the cable retention
arm.
Figure 2-9. Attaching the Cable Retention Arm
For easy installation of the cable retention arm,
Setting Up the System 2-13

Advertisement

Table of Contents
loading

Table of Contents