Service Manual – SC100 - Scrubtec 130
Disassembly/assembly of the sensor receiving the solution level
Disassembly
1
Set the machine to stop position
2
Make sure that the machine power supply cable is disconnected from the electrical mains
3
Remove the tank assembly
4
Remove the screws (A)
5
Lift and move aside the cover (B)
6
Disconnect the function electronic board (E) and the electrical connector (C) of the sensor (D)
Warning!
Take care when handling the function electronic board (E) to prevent its circuits and
components from damage.
7
Disengage the fasteners (G) and the wiring harness (F) of the sensor (D)
Remove the sensor (D) from the housing (H) and retrieve it with the wiring harness
Assembly
8
Assemble the components in the reverse order of disassembly
B
A
D
F
E
Solution System
H
D
G
G
C
30