Function Electronic Board Disassembly/Assembly - Nilfisk-ALTO SC100 Service Manual

Table of Contents

Advertisement

Service Manual – SC100 - Scrubtec 130

Function Electronic Board Disassembly/Assembly

Disassembly
1
Set the machine to stop position
2
Make sure that the machine power supply cable is disconnected from the electrical mains
3
Remove the tank assembly
4
Remove the screws (A)
5
Lift and move aside the cover (B)
6
Disconnect the electrical connections (D) from the function electronic board (C)
7
Loosen the two screws (E) and remove the function electronic board (C) by disengaging it from the
fasteners on the lower sides (F)
Warning!
When the function electronic board (C) is reused or replaced, take care when
handling it to prevent its circuits and components from damage.
Assembly
8
Assemble the components in the reverse order of disassembly
B
A
E
D
C
D
F
D
Electrical System