Menu
Zebra Pattern
Line
Modulation
Capture
Load
Rename
Delete
Internal Signal
Function Switch
Scan Mode
68
Display Function Menu
Function and operation ([
Sets the zebra pattern displayed in the clipped portions.
Note
When the setting for the zebra pattern is changed, Zebra Pattern of Gamut Error Display is
also set to the same setting value.
Sets the direction of the pattern.
[Diagonal Type1]: Right descending
Diagonal Type2: Left descending
Sets the amplitude of the pattern display.
Set to 1 to 50. [16]
Captures the still picture for the standard of the color evaluation.
Loads the captured picture from the "Memory Stick".
When the item is selected, you can select the file name to be loaded.
Changes a file name of the captured picture in the "Memory Stick".
When the item is selected, the file names are displayed.
When the file name is selected, you can change the file name (1 to 20 characters).
Existing file name: Enter the existing file name.
New Name: Enter a new file name.
Note
The "." must not be used as the first character.
Deletes the file of the captured picture in the "Memory Stick".
When the item is selected, the file names in the "Memory Stick" are displayed.
When the file name is selected, the following message appears.
Delete this file?
OK: To delete the data, press the ENTER (Ent) button.
Cancel: To cancel, press the MENU button.
Selects the internal signal display.
You can select from PLUGE, Gray (20% gray signal), White (100% white signal), 5 step (5
step gray scale signal), Ramp, Color Bars or Black (0% black signal).
To cancel the internal signal, select one from the channel numbers 1 to 30 with the numeric
buttons of the controller.
Note
Internal Signal is not set in the following cases:
• When the XYZ or DVI Computer format signal, or HDMI computer signal is input
• When Side by Side is set to On
• When Wipe is set to On
• When Butterfly is set to On
• When Blending is set to On
Sets the function to be assigned to the function button of the controller in the menu.
Sets the scan size of the picture.
[Normal Scan]: Normal scan
Under Scan: 3% under scan
Over Scan: Mask of 5% over scan portion in the normal scan
Note
The scan size is not selectable in the following cases:
• When Native Scan is set to On
• When the input signal has no sync signal
• When the internal signal is displayed
• When Side by Side is set to On
• When Wipe is set to On
• When Butterfly is set to On
• When Blending is set to On
]: factory setting)