1.12 HOME LEAVE Operation

Outline
Floor / Ceiling Suspended Dual Type, Duct Connected Type
HOME LEAVE operation is a function that allows you to record your favorite set temperature
and airflow rate. You can start your favorite operation mode simply by pressing the [HOME
LEAVE] button on the remote controller.
Detail
1. Start of Function
The function starts when the [HOME LEAVE] button is pressed in cooling mode, heating mode
(including POWERFUL operation), or while the operation is stopped. If this button is pressed in
POWERFUL operation, the POWERFUL operation is canceled and this function becomes
effective.
2. Details of Function
A mark representing HOME LEAVE is indicated on the display of the remote controller. The
indoor unit is operated according to the set temperature and airflow rate for HOME LEAVE
which were pre-set in the memory of the remote controller.
The LED (red) of indoor unit representing HOME LEAVE lights up. (It goes out when the
operation is stopped.)
3. End of Function
The function ends when the [HOME LEAVE] button is pressed again during HOME LEAVE
operation or when the [POWERFUL] button is pressed.

"HOME LEAVE operation"

set temp.
"HOME LEAVE operation"
set temp.
Others
The set temperature and airflow rate are memorized in the remote controller. When the remote
controller is reset due to replacement of battery, it is necessary to set the temperature and
airflow rate again for HOME LEAVE operation.
Function and Control
The [HOME LEAVE] button is ineffective in dry mode and fan mode.
<Cooling>
Set temp.
Normal operation
<Heating>
Set temp.
Normal operation
Indoor Unit Control (RA Models)
HOME LEAVE operation
Start
Stop
HOME LEAVE operation
Start
Stop
Normal operation
Time
(R1366)
Normal operation
Time
(R1367)
91