Hot Start Control (In Heating Operation Only) - Daikin 3MKS50E3V1B Service Manual

Super multi nx e / f / g / k-series
Hide thumbs Also See for 3MKS50E3V1B:
Table of Contents

Advertisement

Indoor Unit Control (SA Models)
2.4

Hot Start Control (In Heating Operation Only)

Outline
At startup with thermostat ON or after the completion of defrosting in heating operation, the
indoor unit fan is controlled to prevent cold air from blasting out and ensure startup capacity.
Detail
104
Defrost ending or oil return ending
or Thermostat ON
Hot start control
H/L remote
controller setting
LL
OFF
Remote controller
setting
Level position
Hot start in progress
The fan is not OFF before initiating the hot start: LL
The fan is OFF before initiating the hot start: OFF
TH
: Temperature (°C) detected with the gas thermistor
2
TC : High pressure equivalent saturated temperature
SiBE121135
Hot start ending conditions
·
lapse of 3 minutes
·
OR
[TH
] > 34˚C
2
·
Tc > 52˚C
Normal operation
Normal operation
Function and Control
(R15421)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents