Removal Of Fan Motor - Daikin 3MKS50E3V1B Service Manual

Super multi nx e / f / g / k-series
Hide thumbs Also See for 3MKS50E3V1B:
Table of Contents

Advertisement

Outdoor Unit: 80/90 Class
2.4

Removal of Fan Motor

Procedure
Step
1
Remove the 2 lower
screws of the fan motor.
2
Remove the 2 upper
screws.
3
Remove the fan motor.
392
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
2
1
Fan motor
(R10414)
Be sure to remove the lower
screws first. If the upper
screws are removed first, the
fan motor may tilt or fall
because the center of its
gravity is toward the front.
It may cause injuries.
(R6442)
When reassembling, be sure
to place the wire harness
lower.
(R10542)
SiBE121135
Points
Harness
(R6444)
Removal Procedure