Temperature Control Unit/Regulator/Starter Motor Relay/Ignition Unit; Checking The Carburettor Heating Circuit - PEUGEOT SpeedFight 3 Workshop Manual

4t
Hide thumbs Also See for SpeedFight 3:
Table of Contents

Advertisement

ELECTRICITY
Temperature control
unit/Regulator/Starter motor relay/Ignition
unit
- Remove the storage compartment. See:
Procedure 1 page 19.
- Remove:
• Regulator (1).
• The starter motor relay (2).
• The ignition module (3).
• The temperature control unit (4).

Checking the carburettor heating circuit

Power supply range of the carburettor heating
resistor:
±2
Between 10
and 20
Disconnect the temperature control unit
and take the measurements on the
harness side.
• Between the green wire and the ground: 0 .
• Between the white/yellow wire and the ground
(Resistor warming carburator):
±20%
8.5
.
• Between the black wire and the ground,
ignition on: 12 V (Battery voltage).
• Between the yellow wire and the ground,
engine running: 13.5 V (Regulated alternating
current).
- If the values are correct, replace the
temperature control unit.
- If the values are incorrect, check:
• The harness.
• The ignition switch.
• The carburettor heating resistor: 8.5
48
Reproduction or translation, even partial, is forbidden without the written consent of Peugeot Motocycles
±2
° C.
±20%
3
.
2
4
1