Protection; Mains; Trigger; Mechanical - Lyngdorf Audio SDA 2175 Owner's Manual

Compact analog power amplifier
Table of Contents

Advertisement

Protection

Parameter
Grounding
Output short circuit current
Output DC voltage
Over-temperature

Mains

Parameter
Mains input connector
Mains voltage range
Mains voltage range
Internal mains fuse
Internal mains fuse
Power consumption
Power consumption
Power consumption
Power consumption

Trigger

Parameter
TRIGGER IN connector
TRIGGER BYPASS connector 3.5 mm (1/8") mono jack
TRIGGER IN impedance
TRIGGER IN sensitivity
Max. input voltage

Mechanical

Parameter
Width
Depth
Depth
Height
Height
Net weight
Shipping weight
Value
Mains earth, chassis and audio
ground are connected
internally.
±40 A
±5 V @ <0.1 Hz
All heatsinks and mains
transformer
Value
IEC 320 cold type
100-120 VAC, 50–6 0Hz
200-240V AC, 50-60Hz
8 Amp
4 Amp
1.5 W
35 W
116 W
820 W
Value
3.5 mm (1/8") mono jack
10 Kohm
4 VDC or 4Vp AC
±25 Vp
Value
450 mm (17.72")
340 mm (13.39")
361 mm (14.21")
88.8 mm (3.5")
100.6 mm (3.96")
15.5 kg (34 lb.)
17.5 kg (39 lb.)
11
Note
Note
Mains lead supplied
115 V version
230 V version
115 V version
230 V version
STANDBY mode
OPERATE mode, no output.
2 x 37.5 W/4 Ohms
2 x 300 W/4 Ohms.
Note
Case=Gnd, Tip=Input
Case=Gnd, Tip=Output
Positive DC voltage on Tip. AC
> 50 Hz
Note
Excluding loudspeaker
connectors.
Including loudspeaker
connectors.
Excluding feet.
Including feet.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents