16
InfO MODE
Light Ring yES/nO:
The light ring provides visual cues in regards to oven
operation and how much cook time is remaining.
VAC yES/nO:
When VAC is set to YES the incoming voltage will be
displayed on the Info screen. This is set by the factory
and should not be changed.
Demo Mode yES/nO:
Demo Mode is a feature used to demonstrate the
cooking features of the oven without turning on the
heaters or microwave system. Demo Mode must be
set to NO during regular operation.
Manual Cooking yES/nO:
When Manual Cooking is set to YES, the operator
can cook items "on the fly." See page 13 for more
details.
Diagnostic Mode yES/nO:
Diagnostic Mode is helpful for monitoring oven data
while performing test cooks. When Diagnostic Mode
is turned on, the oven will show the following infor-
mation during cooking:
- Event currently being cooked
- Time left per event
- % wave and % air
- Top/bottom heater power sharing
(Stone "No" = 50/50, Stone "Yes" = 30/70)
- Status indicators
- Group and recipe name
- Top/bottom heater temperature
- CC set point
To turn Diagnostic Mode on or off, press the key
adjacent to "Diagnostic." For normal oven opera-
tion, Diagnostic Mode should remain off.
f2 Bypass yES/nO:
The F2 alarm indicates the oven temperature is too
low. YES means the oven will not terminate a cook
cycle when an F2 alarm is encountered. The oven will
still log the fault condition. NO means the oven will
function as it normally would; i.e., when an F2 alarm
is discovered during a cook cycle, the oven will termi-
nate the cook cycle.
Cooking Stone yES/nO:
The "Stone" option should be set to:
- "YES" if a baking stone is being used
- "NO" if only a wire rack is being used
"YES" increases the temperature of the bottom half
of the oven for optimal cooking results when a stone
is being used. Changing this setting is not recom-
mended, except for cook setting developers as it can
adversely impact cook results.
Info Mode: Settings Screen
From the Information or Counters screen, touch
"Login" to access the Settings screen. When
prompted, input the password
touch "ENTER."
figure 10: Info Mode, Settings Screen
from the settings screen, set:
- Temperature
- Language
- Ethernet
- Volume
- Date
- Time
- Auto On
- Auto Off
Temperature:
The temperature measurement setting is configured at
the factory. Touch °F (Fahrenheit) or °C (Celsius) to
change the temperature measurement settings.
9 4 2 8