Operator Controls; Charge Indicators; Charging Batteries; Troubleshooting - Psion EP10 User Manual

Hand-held computer
Hide thumbs Also See for EP10:
Table of Contents

Advertisement

Chapter 6: Peripheral Devices & Accessories

Operator Controls

Important: If you choose to wall mount the charger, detailed installation instructions are
6.7.3

Operator Controls

The gang charger does not have operator controls or a power switch. There is no dedicated indicator light
to show that the charger is powered, but the charge slot LEDs will light.
6.7.4

Charge Indicators

Each battery charge slot is equipped with four LEDs to indicate the charge status of the battery. When the
EP10 batteries are inserted in the charger, the colour and behaviour of the LEDs associated with the charge
wells in use indicate the status of the charge.
Charge Status Indicator LEDs
Table 6.2
Charge LED Behaviour
OFF
Solid Green
Flashing Green
Flashing Yellow
Solid Red
6.7.5

Charging Batteries

Slide an EP10 battery, as shown, into each charge compartment until the battery touches the base of
the charge compartment. Ensure that the contacts on the battery meet the contacts in the battery
charge bay.
The 4-LED bar for the battery bay shows 25% charger per LED. A flashing green LED shows charging is
under way. The LED directly below the slot in which a battery is inserted lights up immediately. If the
battery temperature is outside 0° C and 40° C (32° F to 104° F), the LED flashes yellow until the tempera-
ture is acceptable. A fully discharged battery will normally take from 3 to 4 hours to charge. At full capacity,
it turns solid green.
When the battery is fully charged, the charger stops applying power; the battery cannot be overcharged if
left in the charger slot.
6.7.6

Troubleshooting

6.7.6.1

Improper Battery Storage

Storing batteries in the gang charger for extended periods (more than a week or two) is not recommended.
Lithium-ion batteries lose capacity if they are maintained at full charge for long periods of time. See the
battery handling recommendations in "The Battery" on page 17.
6.7.6.2

Indicator Does Not Light When Battery Installed

Remove the battery, and clean the contacts on the battery and the charge slot.
Reinstall the battery, and check that it is fully seated in the slot.
Inspect the charge slot contacts for damage (are they bent, flattened, twisted or broken).
Try inserting a battery that you know to be working in the charger slot.
Reconnect the mains power cable, and check that the slot indicator flashes at power up.
206

Psion EP10 Hand-Held Computer User Manual

included in the 'EP10 RV3004 Charger Spare Battery 4 Slot Quick Start Guide'
(PN 8000233) included with the quad charger. Be sure to locate the charger in an
area where there is no risk of injury to persons walking in the vicinity.
No battery detected.
Battery charging complete.
Charge in progress.
Battery is not charging due to out-of-temperature conditions.
Unable to read battery or non Psion battery.