Broil King P3X-1 Owner's Manual page 30

Hide thumbs Also See for P3X-1:
Table of Contents

Advertisement

TROUBLESHOOTING
Although the manufacturer has attempted to ensure that your grill will operate properly and satisfactorily,
sometimes problems do arise. The following troubleshooting guide lists several possible problems and
their probable cause and solution.
Problem
Burner will not light.
Inadequate grill tem-
perature.
Flames blow out.
Yellow flames.
Page 30
Cause
Gas injector not inserted in venturi
tube.
Clogged gas injector.
Obstruction in gas line.
Spider webs in venturi tubes.
Misalignment of collector box and
burner.
Out of gas
Dead battery.
Poor combustion.
Misalignment of venturi tube and
gas injector.
Inadequate gas pressure.
Incorrect orifice/valve setting.
Cold grill.
Misalignment of burner tube and
gas injector.
Poor combustion.
Extreme wind.
Air shutter improperly set.
Spider webs in venturi tubes.
Seasoning salts on burner.
Oil film on burner.
Solution
Realign/engage gas injector with
the venturi tube.
Remove gas injector from gas con-
trol assembly and clean.
For propane models, ensure gas
valve on cylinder is OFF. Remove
flexible hose and blow out any
debris.
Clean venturi tubes. See Mainte-
nance Section.
Position electrode properly. Clean
collector box.
Refill LP gas cylinder. If natural
model, turn on gas at source.
Replace with AA Alkaline battery.
Adjust air shutter.
Realign/engage gas injector with
the venturi tube.
Contact gas supplier for assistance.
Refer to gas conversion instructions
in this manual.
Preheat grill at least 5 minutes on
HI with the grill lid closed.
Realign/engage gas injector with
the burner tube.
Adjust air shutter.
Turn or shield grill.
Open air shutter
Clean venturi tubes. See Mainte-
nance Section.
Clean by washing burner with mild
detergent.
Allow burner to operate on HI for
10-15 minutes.
B101525-2-0211

Advertisement