Flushing The Unit - WAGNER FLEXiO 990 Owner's Manual

Hide thumbs Also See for FLEXiO 990:
Table of Contents

Advertisement

Cleanup

Flushing the Unit

Before you begin:
When cleaning, use the appropriate cleaning solution
(warm, soapy water for latex materials; mineral spirits for
oil-based materials)
IMPORTanT: never clean air cap or air holes in
the nozzle with sharp metal objects. Do not use
solvents or lubricants containing silicone.
Special cleanup instructions for use with
flammable solvents (must have a flashpoint
above 100ºF (38ºC):
• Always flush spray gun outside.
• Area must be free of flammable vapors.
• Cleaning area must be well-ventilated.
• Do not submerge turbine!
1. Unplug the power cord. Loosen the material container
by 1/2 turn, but do not remove it. This will relieve any
pressure left over in the system.
Pull the trigger so that the material inside the spray
nozzle drains back into the container.
2. Unscrew the container and remove. Empty any
remaining material back into the material container.
Pour a small amount of the appropriate cleaning
solution into the cup (Water=1/2 full. Mineral
spirits=1/4 full).
3. Attach the cup to the nozzle and plug in the sprayer.
Spray the cleaning solution into a safe area.
While spraying, gently shake the spray gun. This slight
agitation will help break up smaller particles of spray
material.
4. Unplug the power cord. Loosen the material container
by 1/2 turn, but do not remove it. This will relieve any
pressure left over in the system.
Pull the trigger so that the material inside the spray
nozzle drains back into the container.
IMPORTanT: If you cleaned the sprayer using
mineral spirits, repeat steps 1-4 using warm, soapy
water.
Move on to "Cleanup - Cleaning the nozzle", next page.
© Wagner Spray Tech. - All Rights Reserved
(Control Finish Nozzle only)
1
1/2
PULL
2
3
4
1/2
PULL
English
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents