Assigning RAID Levels

Only one RAID level can be assigned to each logical drive. The drives required per RAID level
are:
RAID
Level
10
30
50

Configuring Logical Drives

After you have installed the MegaRAID controller in the server and have attached all physical disk
drives, perform the following actions to prepare a RAID disk array:
Step
1
2
3
4
5
6
7
42
MegaRAID Enterprise 1600 Hardware Guide
Minimum Number of
Physical Drives
0
One
1
Two
3
Three
5
Three
Four
Six
Six
Optimize the MegaRAID controller options for your system. See Chapter 3
for additional information.
Press <Ctrl> <M> to run the MegaRAID Manager.
Perform a low-level format of the SCSI drives that will be included in the
array and the drives to be used for hot spares.
Define and configure one or more logical drives. Select Easy Configuration
in MegaRAID Manager or select New Configuration to customize the
RAID array.
Create and configure one or more system drives (logical drives). Select the
RAID level, cache policy, read policy, and write policy.
Save the configuration.
Initialize the system drives. After initialization, you can install the
operating system.
Maximum Number of Physical
Drives
32
Two
32
32
32
32
32
Action

Advertisement

Table of Contents
loading