Programming Troubleshooting

Symptom
Lock does not respond – door is open
and accessible.
Lock does not respond – door is
locked and inaccessible.
The unit is on for a while, and then
shows no reaction. Lights dim.
Unit chimes to indicate code accep-
tance, but the door will not open.
Unit operates to allow access, but will
not automatically re-lock.
PIN codes will not register.
Upon entering a PIN code and press-
ing the star (*) key, the unit displays
an "invalid code" error or the lock
times out without responding.
Upon entering a PIN code and press-
ing the (*) key, the red padlock icon
appears and there are different tones.
The unit operates, but it makes
no sound.
The unit responds "Low Battery"
Upon entering a PIN code and press-
ing the star (*) key, the unit responds
"Wrong number of digits."
* When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface; it is
recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).
** Network module units only
An ASSA ABLOY Group brand
Suggested Action
The touchscreen will become active when pressed with the back of hand or fingers in at least
3 areas simultaneously.
Use a larger area of the hand or fingers and verify contact with at least 3 areas.
If touchscreen numbers are visible, check to see if they respond when pressed.
Check batteries are installed and oriented correctly in the battery case.
Check batteries are in good condition; replace batteries* if discharged.
Check to see if touchscreen wire harness is fully connected and not pinched.
Lock may be in Privacy mode (set from inside room). Mechanical key will grant access.
Batteries may be completely discharged.
Use mechanical key to gain entry and replace batteries*.
The batteries do not have enough power. Replace the batteries*.
Check to see if there is an existing lock device on the door.
Check the door gaps for any foreign objects between door and frame.
Check that the wire harness is firmly connected to the PCB.
Automatic Re-Lock has been disabled; enable in Menu Mode Advanced Settings.
If low battery indicator is lit, replace batteries*.
Registration/management of PIN codes is set by the authority of Master Code.
The Master PIN code must be registered prior to adding any users.
PIN codes must consist of 4 to 8 digits to register.
The same PIN code cannot be used for multiple users.
Contact the Master user.
User codes must be entered within 5 seconds (while the touchscreen is active) or the process
will have to be restarted.
The star
(*) or pound
(#) can not be used as part of the PIN code.
All Code Lockout Mode is enabled.
Only the Master Code can enable All Code Lockout Mode.
Contact the Master user.
Check to see if lock is set** at All Code Lockout Mode.
Setting/managing All Code Lockout Mode is done through Master Code only. Contact the
Master user.
Check to see if Silent Mode is enabled (pages 8, 11).
This is the voice alarm alerting that it is time to replace the batteries. Replace all four (4)
batteries with new AA Alkaline batteries*.
The digits entered were incorrect or incomplete. Re-enter the correct code.