Download Print this page
Yale YRC216 Installation And Programming Instructions

Yale YRC216 Installation And Programming Instructions

Electronic interconnected push button

Advertisement

Quick Links

Yale Assure Lock
®
®
Electronic Interconnected Push Button
®
Installation and Programming Instructions
(YRC216)
Inside
Outside
of Door
of Door
4" Touchscreen Shown - 5.5" Available
Before you begin
Network Module
(Optional)
DOWNLOAD
THE BILT APP
for step-by-step installation
instructions & to register
your product
Retrofitting or modifying this product may impact fire rating, safety features and warranty.
Consult with code specifications to ensure compliance with all codes and ratings.
1
P/N
YRL EMICL PBINSTL FUL
-
-
-
Rev B

Advertisement

loading

Summary of Contents for Yale YRC216

  • Page 1 Yale Assure Lock ® ® Electronic Interconnected Push Button ® Installation and Programming Instructions (YRC216) Inside Outside of Door of Door 4" Touchscreen Shown - 5.5" Available Before you begin Network Module (Optional) DOWNLOAD THE BILT APP for step-by-step installation instructions &...
  • Page 2: Before You Begin

    Before You Begin Template Network Module (Optional) 1/8" 3/32" 1/8" 1" 2-1/8" 4-1/2" (114) 1-3/8" (35mm) Min to 1-3/4" (44.5mm) Max YRL EMICL PBINSTL FUL Rev B...
  • Page 3 Mark Door Reference Lines EXISTING 2-3/8" or 2-3/4" Backset Template YRL EMICL PBINSTL FUL Rev B...
  • Page 4 Preparing Door (if necessary) Template 4" 5.5" 2-3/8" Ø2-1/8" Ø1" 2-3/4" Drill holes 1/2 way thru door then complete from other side to prevent splitting. YRL EMICL PBINSTL FUL Rev B...
  • Page 5 Installing Strike Plates 7-16 / 8-32 x 1" UNCWS Frame 1" Dia. x 1"Deep Frame Inside of Door 1" Dia. x 1/2"Deep Door Frame YRL EMICL PBINSTL FUL Rev B...
  • Page 6 Determining Handing The hand of a door is determined from the secure side of the door. The term "secure" means the side from which you initially unlock and enter. Left Hand “ ”, Hinges Left. Left Hand Reverse " ", Hinges Left. Open Inward.
  • Page 7 Changing Handing (if necessary) 4" Left Hand to 4" Right Hand Shown 4-24 x 1/4" PPHMS DO NOT TAMPER WITH OR LOOSEN E-CLIP AND ITS ASSEMBLY DO NOT LOOSEN THESE 6 SCREWS OR REMOVE COVER YRL EMICL PBINSTL FUL Rev B...
  • Page 8 Changing Handing (if necessary) continued YRL EMICL PBINSTL FUL Rev B...
  • Page 9 Lockset Handing Configurations For 5.5" For 5.5" For 4" 4" Right Hand For 4" 4" Left Hand Test Lever and Thumbturn After handing is changed, check that lever and thumbturn rotate freely. YRL EMICL PBINSTL FUL Rev B...
  • Page 10 Installing Fire Cups Inside of Door Both Fire Cups and a marked Latchbolt must be used to qualify for listing. YRL EMICL PBINSTL FUL Rev B...
  • Page 11 Adjusting Deadbolt Latch (If adjustable deadbolt latch provided) default 2-3/8" position optional 2-3/4" position Pull Press YRL EMICL PBINSTL FUL Rev B...
  • Page 12 Installing Deadbolt Latch & Latchbolt 7-16 / 8-32 x 1" UNCWS Inside of Door Bolt must be in retracted (unlocked) position before installing. Ensure arrow stamped on deadbolt Choose latchbolt based on backset. (2-3/8" or 2-3/4") Curved edge of latchbolt faces direction door closes.
  • Page 13 Installing Exterior Deadbolt M6x55 PPHMS Inside of Door YRL EMICL PBINSTL FUL Rev B...
  • Page 14 Installing Lock Chassis 10-32 x 1-1/2" PPHMS Inside of Door YRL EMICL PBINSTL FUL Rev B...
  • Page 15 Securing Back Plate to Door #6-32 x 1/2" POHMS Inside of Door Drill two pilot holes Ø1/8" x 1/2" deep Two #6-32 x 1/2" POHMS screws must be used to qualify for listing. YRL EMICL PBINSTL FUL Rev B...
  • Page 16 Testing Deadbolt & Latchbolt Operation Outside of Door YRL EMICL PBINSTL FUL Rev B...
  • Page 17 Attaching the Cable Assembly Test that cables are securely connected. Inside of Door Cable must be routed as shown to avoid interference with movement of lock. YRL EMICL PBINSTL FUL Rev B...
  • Page 18 Installing Interior Lock Orientation must match. Do not fasten lock to back plate until properly fitted. Inside of Door Turn thumbturn to adjust slot orientation. YRL EMICL PBINSTL FUL Rev B...
  • Page 19 Installing Interior Lock continued 10-32 x 5/8" POHMS 6-32 x 1" PPHMS Inside of Door DO NOT LOOSEN THIS SCREW YRL EMICL PBINSTL FUL Rev B...
  • Page 20 Installing Interior Lever Inside of Door " SNAP " Inside of Door Pull lever to ensure it is secure. YRL EMICL PBINSTL FUL Rev B...
  • Page 21 Testing Final Latchbolt Operation Inside of Door Outside of Door YRL EMICL PBINSTL FUL Rev B...
  • Page 22 Testing Final Deadbolt Operation YRL EMICL PBINSTL FUL Rev B...
  • Page 23 Testing Final Deadbolt Operation If testing fails, go back to beginning of Step 11 and check installation. YRL EMICL PBINSTL FUL Rev B...
  • Page 24 Installing Optional Network Module DO NOT install network module with batteries in unit. Damage may occur. Installing Batteries & Cover Tighten screw to replace cover. Bolt must be in retracted (unlocked) position before installing batteries. YRL EMICL PBINSTL FUL Rev B...
  • Page 25: Handing The Lock

    Select Press to complete Lock will cycle motor to complete handing. Congratulations, you've installed the Yale Assure Lock Electronic Interconnected Push Button! ® ® Continue with the Programming Instructions to customize your product. YRL EMICL PBINSTL FUL Rev B...
  • Page 26: Hardware Troubleshooting

    Hardware Troubleshooting Cycle lock in both the locked and unlocked positions. If problems are found: Bolt will not extend and motor is grinding a. Enter your Master code. b. With the bolt retracted, press menu Option 3 for Advanced Lock Settings. c.
  • Page 27 Changing Lock: Replacing Cylinder 1. To remove cylinder: A. Remove keypad from door. B. Remove rubber gasket. C. Remove two screws holding plastic guide in place. D. Remove plastic guide. E. Remove screw with washer holding cylinder in place (visible after removing plastic guide).
  • Page 28: Programming Instructions

    Programming Instructions Low Battery Warning- Flashes RED Lock-out Mode- Keypad Flashes Interior Lock Privacy Mode Button Keypad Master Code must be created before any further programming. Max User Codes = 250 with Z-Wave Plus or ZigBee network module Max User Codes = 25 without network module or with iM1 network module Max User Codes - 12 with Bluetooth YRL EMICL PBINSTL FUL Rev B...
  • Page 29 Creating Master Code Creating a Master Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. Press Press Press Enter 4-8 digit Master Code.
  • Page 30: Creating User

    Creating User Codes Master code must be created first. *Max user codes = 250 with Z-Wave Plus or ZigBee network module Max user codes = 25 without network module or with iM1 network module Max user codes - 12 with Bluetooth Enter Master code Press...
  • Page 31: Code Chart

    Unlocking Door with Code Enter PIN Press "Unlock" Code Chart Duplicate if necessary PIN Code Management (With Network Module - Up to 250 Users) User Type User Name PIN Code Master User User User User User User User User User User User User...
  • Page 32: Factory Settings

    Resetting Lock to Factory Default Interior Lock When resetting the lock, all user codes, including the Master code*, are deleted. All (4" Shown) programming features are reset to original default settings (see below). 1. Remove the battery cover and batteries. 2.
  • Page 33 Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) code access. When attempting to enter a code while the unit is in Lockout, the keypad flashes 8 times and the lock beeps 3 times as well.
  • Page 34 Feature Programming Through Menu Mode Using Master code* 1. Enter 4-8 digit master code* followed by key. 2. Enter digit corresponding to the function to be performed followed by the key. *The Master code must be registered prior to any other programming of the lock. Note: After Master code is entered, lock will automatically hand itself.
  • Page 35: Programming Troubleshooting

    Programming Troubleshooting Symptom Suggested Action • Press each keypad button for response when pressed. • Check batteries are installed and oriented correctly (polarity) Lock does not respond – in the battery case. door is open and • Check batteries are in good condition; replace batteries* accessible.
  • Page 36 Product Support Tel 1-855-213-5841 • www.yalehome.com Yale® ,Yale Real Living® and Assure Lock® are registered trademarks of Assa Abloy Residential Group. Other products' brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. © Copyright 2018. All rights reserved. Reproduction in whole or in part without the express written permission of Assa Abloy Residential Group is prohibited.
  • Page 37 Yale Z -Wave Plus Module ® ® ® Installation and Programming Instructions Installing the Z -Wave Plus Module ® IMPORTANT: the batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover and batteries. • Remove and/or insert Network Module.
  • Page 38 Copyright © 2017, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. YALE, with its unique global reach and range of products, is the world's favorite lock –...
  • Page 39 Yale ZigBee Module ® ® ® Installation and Programming Instructions Installing the ZigBee Module ® IMPORTANT: the batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover. • Remove batteries. • Remove and/or insert network module.
  • Page 40 Copyright © 2017, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. YALE, with its unique global reach and range of products, is the world's favorite lock –...
  • Page 41 • Reinstall batteries and battery cover. Enrolling the iM1 Network Module: The Yale iM1 Network Module must be used with a Yale Assure Lock or Yale nexTouch Lock and cannot be used in conjunction with any other Yale Network Module.
  • Page 42 Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale®, Yale Real Living® and Assure Lock® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group Company. nexTouch™ is a trademark of Yale Security Inc., an ASSA ABLOY Group Company.

This manual is also suitable for:

Real living assure lock