Summary of Contents for Yale Real Living YAYRL220ZWx
Page 1
Yale Real Living™ Touchscreen Lever Installation and Programming Instructions M4 x 8mm pan head machine screws #7 wood & #8-32 machine x 20mm M4 x 25.4mm Combination screws pan head machine screws Set screws Hex key FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE...
Preparing to Install #2 Phillips Screwdriver 2-3/8" through bolt posts default 2-3/4" through bolt posts optional Note: Adjustment based on backset P/N AYRL-220-INST-FUL Rev D...
Page 3
Determining Lever Handing Left Hand Options The hand of a door is determined from the secure side of the door. The term "secure" means the side from which you initially unlock and enter. Left Hand Left Hand Reverse Hinges Left. Hinges Left.
Page 4
Determining Lever Handing Right Hand Options The hand of a door is determined from the secure side of the door. The term "secure" means the side from which you initially unlock and enter. Right Hand Right Hand Reverse Hinges Right. Hinges Right.
Page 5
Installing Latch & Strike Plate Left Hand Installation Shown Outside of Door Frame Outside of Door Frame P/N AYRL-220-INST-FUL Rev D...
Page 6
Installing Exterior Escutcheon Left Hand Installation Shown Do not remove clip until Step 6 Outside of Inside of Left Hand Door Left Hand Door P/N AYRL-220-INST-FUL Rev D...
Page 7
Installing Interior Mounting Plate Left Hand Installation Shown Loosen screw to remove cover. Inside of Left Hand Door Inside of Left Hand Door Outside of Left Hand Door P/N AYRL-220-INST-FUL Rev D...
Page 8
Attaching the Cable Assembly Left Hand Installation Shown Inside of Left Hand Door Inside of Left Hand Door P/N AYRL-220-INST-FUL Rev D...
Page 9
Installing Interior Escutcheon Left Hand Installation Shown Inside of Left Hand Door P/N AYRL-220-INST-FUL Rev D...
Page 10
Installing Exterior Lever Remove clip. Do not rotate internal cam (marked red). Red mark must remain on top and in position. Outside of Left Hand Door Do Not Do Not Overtighten Overtighten Do Not Turn Do Not Turn Counter Counter Clockwise Clockwise Outside of...
Page 11
Installing Exterior Lever con't Outside of Outside of Left Hand Door Right Hand Door P/N AYRL-220-INST-FUL Rev D...
Page 12
Installing Exterior Lever con't Do Not Do Not Overtighten Overtighten Outside of Outside of Left hand Door Right Hand Door Outside of Outside of Left Hand Door Right Hand Door P/N AYRL-220-INST-FUL Rev D...
Testing Operation Inside of Door Left Hand Door Shown Outside of Outside of Left Hand Left Hand Door Door Right Hand Door Shown Outside of Outside of Right Hand Right Hand Door Door P/N AYRL-220-INST-FUL Rev D...
Page 14
Installing Interior Lever Inside of Inside of Left Hand Door Right Hand Door Do Not Do Not Overtighten Overtighten Inside of Inside of Left Hand Door Right Hand Door Almost done! Turn sheet over to finish installation and customize your product with Programming Instructions. P/N AYRL-220-INST-FUL Rev D...
Page 15
Installing Interior Lever con't Inside of Left Hand Door Do Not Overtighten Inside of Right Hand Door Do Not Overtighten P/N AYRL-220-INST-FUL Rev D...
Page 16
Testing Final Operation Inside of Door Outside of Left Hand Door P/N AYRL-220-INST-FUL Rev D...
Page 17
Testing Final Operation Inside of Door Inside of Door Inside of Left Hand Door P/N AYRL-220-INST-FUL Rev D...
Page 18
Testing Final Operation Inside of Door Outside of Left Hand Door P/N AYRL-220-INST-FUL Rev D...
Page 19
Installing Batteries & Cover "Welcome to Tighten screw to replace cover. Yale Real Living." Inside of Left Hand Door Congratulations, you've installed the Yale Real Living™ Touchscreen Lever! Continue with Programming Instructions to customize your product. P/N AYRL-220-INST-FUL Rev D...
Page 20
Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications to this device, not expressly approved by Yale Security Inc. could void the user's authority to operate the equipment. Industry Canada: This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Programming Instructions "P" Key (Return to Previous) Low Battery Indicator Lockout Mode Speaker Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed.
Page 23
Creating Master PIN Code Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. "Register Master Code. Press the pound key to continue."...
Page 24
Creating User PIN Codes Master PIN code must be created first. *Max user codes = 250 with Network Module. Max user codes = 25 without. "Menu Mode, enter number, press the pound key to continue." Enter Master PIN code Press Enter User number Press Press...
Unlocking Door with PIN Code Enter PIN Code Press Code Chart Duplicate if necessary PIN Code Management (With Network Module - Up to 250 Users) User Type User Name User # PIN Code Master User ___ User ___ User ___ Factory Settings Settings Factory Setting...
Page 26
Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the RED locked padlock will appear on the screen.
Feature Programming Through Menu Mode Using Master PIN code* 1. Touch screen with back of hand or palm to activate. 2. Enter 4-8 digit master PIN code* followed by key. Lock Response: "Menu mode, enter number, press key to continue." 3.
Programming Troubleshooting Symptom Suggested Action • Touchscreen becomes active when pressed w/whole hand. Use a larger area of the hand or fingers and verify contact Lock does not respond – with at least 3 areas. door is open and • If touchscreen numbers are visible, check to see if they accessible.