Yale Real Living YRD240 Installation & Programming Instructions

Yale Real Living YRD240 Installation & Programming Instructions

Key free touchscreen deadbolt

Advertisement

Yale Real Living Key Free Touchscreen Deadbolt
®
®
Installation and Programming Instructions
Optional
Network Module
x3
#8-32 x 5/16"
x4
Machine screws
#7 wood & #8-32
machine x 20mm
Combination screws
x2
M6x47mm
Long through bolt
1
P/N AYRD-240-INST-FUL Rev E

Advertisement

Table of Contents
loading

Summary of Contents for Yale Real Living YRD240

  • Page 1 Yale Real Living Key Free Touchscreen Deadbolt ® ® Installation and Programming Instructions Optional Network Module #8-32 x 5/16" Machine screws #7 wood & #8-32 machine x 20mm Combination screws M6x47mm Long through bolt P/N AYRD-240-INST-FUL Rev E...
  • Page 2 Preparing Door P/N AYRD-240-INST-FUL Rev E...
  • Page 3 Installing Latch & Strike Plate 2-3/8" position d faut 2-3/4" position optional Pull Press Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism. P/N AYRD-240-INST-FUL Rev E...
  • Page 4 Installing Touchscreen Escutcheon Inside of Door Outside of Door Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism. P/N AYRD-240-INST-FUL Rev E...
  • Page 5 Installing Interior Mounting Plate Loosen screw to remove cover. P/N AYRD-240-INST-FUL Rev E...
  • Page 6 Attaching the Cable Assembly P/N AYRD-240-INST-FUL Rev E...
  • Page 7 Installing Interior Escutcheon P/N AYRD-240-INST-FUL Rev E...
  • Page 8: Testing Operation

    Testing Operation Bolt must be in retracted (unlocked) position before installing batteries. P/N AYRD-240-INST-FUL Rev E...
  • Page 9 Installing Batteries/Handing the Lock "Welcome to Yale Real Living." Lock automatically adjusts for proper handing. Installing Optional Network Module Batteries must be removed prior to removing and/or inserting network module. P/N AYRD-240-INST-FUL Rev E...
  • Page 10: Installing Cover

    Installing Cover Tighten screw to replace cover. Congratulations, you've installed the Yale Real Living ® Key Free Touchscreen Deadbolt! Continue with Programming Instructions to customize your product. P/N AYRD-240-INST-FUL Rev E...
  • Page 11: Programming Instructions

    Programming Instructions Exterior Escutcheon "P" Key (Return to Previous) Interior Escutcheon Low Battery Indicator Lockout Mode Speaker Privacy Mode Button Failsafe 9 volt Battery Connection (Use Alkaline battery) Lock Activation Master PIN Code must be created before any further programming. Max User Codes = 250 with Network Module.
  • Page 12 Creating Master PIN Code Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. "Register Master Code. Press the pound key to continue."...
  • Page 13 Creating User PIN Codes Master PIN code must be created first. *Max user codes = 250 with Network Module. Max user codes = 25 without. "Menu Mode, enter number, press the pound key to continue." Enter Master PIN code Press Enter User number Press Press...
  • Page 14: Unlocking Door With Pin Code

    Unlocking Door with PIN Code Enter PIN Code Press Code Chart Duplicate if necessary PIN Code Management (With Network Module - Up to 250 Users) User Type User Name User # PIN Code Master User ___ User ___ User ___ User ___ User ___ User ___...
  • Page 15: Factory Settings

    Resetting Lock to Factory Default When lock is reset to factory defaults all user codes (including the Master PIN code*) are deleted and all programming features are reset to original default settings (see below). 1. Remove the battery cover and batteries. 2.
  • Page 16 Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the RED locked padlock will appear on the screen.
  • Page 17: Feature Programming Through Menu Mode Using Master Pin Code

    Feature Programming Through Menu Mode Using Master PIN code* 1. Touch screen with back of hand or palm to activate. 2. Enter 4-8 digit master PIN code* followed by key. Lock Response: "Menu mode, enter number, press key to continue." 3.
  • Page 18: Programming Troubleshooting

    Programming Troubleshooting Suggested Action Symptom Touchscreen becomes active when pressed w/whole hand. • Use a larger area of the hand or fingers and verify contact Lock does not respond – with at least 3 areas. door is open and • If touchscreen numbers are visible, check to see if they accessible.
  • Page 19: Hardware Troubleshooting

    NOTE TO INSTALLER AND CONSUMER ® While Yale has included several features to prevent lockout (9-Volt battery jumper, low battery warnings), it is still possible for a lockout situation to occur. Because this product ®...
  • Page 20 Yale® and Yale Real Living® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. YALE, with its unique global reach and range of products, is the world's favorite lock –...