Oki Data CONFIDENTIAL
4.2.11 operator panel Assy.
(1) Open the top cover.
(2) Open the multi-purpose tray.
(3) Open the front cover.
(4) Remove the left and right side covers (see sections 4.2.3 and 4.2.4).
(5) Remove the plate shield Assy. (see section 4.2.7, (2)).
(6) Detach and unclamp (at the two points) the FFC of the operator panel Assy.
Multi-purpose tray
44015503TH Rev. 1
.
Top cover
FFC
Clamp
Front cover
(7) Unlatch the operator panel cover Assy. at the two points A to remove it and, at the
same angle as shown left below, remove the operator panel cover.
Operator panel cover Assy.
Unlatched points A
(8) Remove the three screws (silver-colored)
(tool number 1). Be careful about a potential drop of the (black) cap
4. REPLACEMENT OF PARTS
to detach the operator panel Assy.
.
Front cover
78 /