Oki Data CONFIDENTIAL
4.2.19 Holder-switch Assy., low-voltage power supply
fan and low-voltage power supply
When replacing the low-voltage power supply, due to potential electric shock, wear
insulated gloves or be careful not to touch the conductors or terminals of the power
supply directly.
After the AC cord is unplugged, the capacitor may take about one minute to discharge
completely, or could not discharge due to PCB breakdown. Use caution about electric
shock.
(1) Remove the plate shield Assy. (see section 4,2,7, (1) to (3)).
(2) Remove the MPT Assy. (see section 4.2.16, (2)).
(3) Remove the connector
Assy
.
44015503TH Rev. 1
Electric shock hazard.
and the screw (black)
to detach the holder-switch
(4) Remove the image drum motor (see section 4.2.7, (6)).
(5) Remove the reinforcement plate (see section 4.2.8, (2)).
(6) Remove the screw (silver-colored)
voltage power supply fan
.
4. REPLACEMENT OF PARTS
and the connector
to detach the low-
92 /