4. REPLACEMENT OF PARTS
Oki Data CONFIDENTIAL
(5) Remove the eleven screws (silver-colored)
to remove the cover plate
.
(6) Remove the right and left FFC connectors
and the two connectors
from the
relay board (P6y)
, and the connector
from the color-registration Assy
.
Remove the five screws (silver-colored)
to detach color-registration Assy.
.
x 11
x 5