Groups and Scheduled Group 1 Examples
F u n c tio n s 9 0 /9 1 :
Use Function 90 and 91 (see page 27) to create a window of time where if any Group 1 User Code is entered within the
programmed window, a relay will be activated for 2 seconds. The relay can be configured to disarm a burglary control panel. See page 28.
1. Enter Program Mode (if not in already).
2. Connect relay to a burglar control panel with switch input for disarming.
3. Using Function 2, create User 4 with a User Code of "456789":
Press 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 6 1 ^ 3 1 ^ 3 1 ^ 3 .
4. Because User 4 does not have a default Group association, make User 4 a member of Group 1 using Function 35:
Press 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 .
5. Use Function 90 to set the time to open the window (8:30 A.M. all days of the week) allowing any Group 1 member to close the relay for 2
seconds. Note: Only 1 relay closure will occur even if another member of Group 1 enters their User Code. Use Function 91 to set the
time to close the window
Function 90 (Open Window Time) = 8:30 A.M.: Press 6 D 0 0 11^0 6 D 11^0 6 D 11^0 0 3 6 3 11^0 6 * 6
Function 91 (Close Window Time) = 10:00 A.M.: Press 6 3 8 0 6 1 6 3 11^0 6 3 6 1 1 1 ^ 0 11^0 11^0 6 * 6
6
. Exit Program Mode (hold down any key for 3 seconds).
The relay will close, one time only, when a member of Group 1 enters their User Code between 8:30AM and 10:00AM. If a Group 1 User
does not enter their User Code during the specified window, Functions 90/91 remain inactive
• The alarm panel will have to be armed at night by the User or by an automatic schedule function of the alarm panel.
F u n c tio n s 9 2 /9 3 :
Use Function 92 and 93 (see page 28) to create a window of time where if any Group 1 User Code is entered within the
programmed window, Group 4 Users will be enabled.
1. Enter Program Mode (if not in already).
2. Using Function 2, create User 4 with a User Code of "456789":
Press 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 6 1 ^ 3 1 ^ 3 ^ g .
3. Because User 4 does not have a default Group association, make User 4 a member of Group 1 using Function 35:
Press 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 ^ 3 1 ^ 3 1 ^ 3 ^ 3 .
4. Using Function 17, disable Group 4. (Group 4 will need to be "disabled" before it can be "enabled" later).
Press II^O l 6 1 6 3 6 1 .
5. Use Function 92 to set the time to open the window (8:30 A.M. all days of the week) allowing any Group 1 member to enable Group 4. Use
Function 93 to set the time to close the window (10:00 A.M. all days of the week).
Function 92 (Open Window Time) = 8:30 A.M.: Press 6 3 6 0 6 3 6 3 11^0 6 3 11^0 6 3 6 3 1 1 ^ 0 6 * 3
Function 93 (Close Window Time) = 10:00 A.M.: Press6 3 0 3 6 3 6 3 1 1 ^ 0 6 3 6 1 1 1 ^ 0 11^0 11^0 6 3
6
. Exit Program Mode (hold down any key for 3 seconds).
The lock will now enable Group 4 User Codes if User 4 (or any Group 1 member) enters their User Code between 8:30 A.M. and 10 A.M.
If no Group 1 member arrives to enter their User Code between 8:30 A.M. and 10 A.M., Group 4 User Codes will not be enabled and will
remain disabled all day.
• The device will have to be manually locked each night by entering the following command using Function 82:
^ 3 1 ^ 3 1 ^ 3 1 ^ 3
1
• The device can also be programmed to automatically disable Group 4 members each night at 5 P.M. by using Function 82:
1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 0 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 0 1 ^ 0 1 ^ 6
• Test the device by creating User 222 (with User Code 466466) and adding User 222 to Group 4:
8
2
8
2
1 ^ 3 1 ^ 3 1 ^ 8 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 3 1 ^ 6
• Remember to exit Program Mode when programming is complete.
V__
30
(10
A.M. for all days of the week):
2
2
8
4
8
8
4
8
8
8
(cont'd.)