Alarm Lock Trilogy DL4100 Programming Instructions Manual page 16

Standalone access control systems trilogy series
Hide thumbs Also See for Trilogy DL4100:
Table of Contents

Advertisement

USERS (Continued)
User Enable/Disable (By User Number)
• User Number must be between 2 and 2000.
NOTE: Will Enable/Disable Users even if the User is associated with an enabled Group. Use Feature 3 to disable a specific User
Number and their associated User Code. If the disabled User Code is entered, the lock will flash 1 Green and 4 Red Flashes (with
1 long and 5 short beeps) indicating that the User Code exists in memory, but is disabled. Function 4 will "undo" Function 3.
3. Disable User
4. Enable User
5. User Enable with Timeout
(Enter Timeout, XXX Hours)
(This Function enabled through keypad only)
With Function 5, User Numbers must be between 2-2000, hours must be between 1-999.
Function 5 can temporarily override a disabled User (disabled using Function 3 above).
Since this is a temporary feature, Function 5 can only be enabled using the keypad.
Example: Brian, User Number 1157, rarely works at the office, but when he does, enable him for his
Program Mode and pressing: II^O l 11^3 II^O l I I C P l ll C P l ll ^ 3 ^ ^
NOTE: Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to program more
than 4 Timeout Functions.
User Lockout Mode
Prevents all User Codes (Except User 1 Code) from operating the lock. Note: No other programming
functions or schedules will re-enable Users. Users must be re-enabled with Function 7.
Note: Does not change the User enable/disable status. Note: If the lock is currently in Passage Mode
(door "unlocked") and Function
6. Enable Total User Lockout Mode
(This Function enabled through keypad only)
Note: Do not use this function with Passage Mode.
7. Disable Total User Lockout Mode
(This Function enabled through keypad only)
8. Reserved
9. Enable User 300
Service Code is a One-Time-Only Code. Once it is used, it is disabled until enabled again.
NOTE:
User Number 297 is used to reset Service Code Use. See "Terminology Used in
this Manual" on page 7 for more information and examples regarding special Users 297-300.
10. Erase All Users Except the Master Code
(This Function enabled through keypad only)
Erases all User Codes except the Master Code (User 1).
• Function 10 can only be performed using the keypad.
11. Reserved
16
Programming Functions (cont'd)
6
is programmed, the lock will remain in Passage Mode.
(Service Code)
3
;
;
[ ______ ] :
(User Number)
4
;
;
[ ______ ] :
(User Number)
;
[ ______ ]
(User Number)
11^3 1 1 ^ 3 1 1 ^ 3 3 ^ 1 IICQl.
I^Q
1^3
1
(User
)
2
II^ P l [ ______ ] IICQl
(XXX Hours)
8
hour work day by entering
M
M
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trilogy dl4500Trilogy dl4100 seriesTrilogy dl4500 series

Table of Contents