r
CLEAR FUNCTIONS
12. Clear All Schedules and Timeout Functions
Function 12 clears all programmed Schedules and all Timeout Functions. (To clear All Timeout Functions only, see
Function 13 below). Function
5, 25 through 34 and Function 47. Note: Function 12 also resets Passage Mode and any disabled Groups. After using
Function 12, your Scheduled/Timeout features must be manually re-programmed.
NOTE:
Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to
program more than 4 Timeout Functions.
13. Clear All Timeout Functions
(This Function enabled through keypad only)
Function 13 clears all Timeout Functions. (To clear All Schedules and Timeout Functions, see Function 12 above).
Function 13 will clear all of the following: All Timeout Functions 5, 25-34 and Function 47. After using Function 12, your
Scheduled/Timeout features must be manually re-programmed.
NOTE:
Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to
program more than 4 Timeout Functions.
Important: It is the responsibility of the lock programmer to verify the proper lock/unlock conditions and Group conditions
after programming the lock with Function 12 and 13.
Group Enable/Disable
Enter the functions below to Enable/Disable Groups. Functions 14 - 23 will each override
existing scheduled events. Therefore, Functions 14 - 23 are temporary, take effect im­
mediately, and are always overridden by future scheduled events that already exist within
the lock programming.
14. Disable Group 1
15. Disable Group 2
16. Disable Group 3
17. Disable Group 4
18. Disable All Groups
19. Enable Group 1
20. Enable Group 2
21. Enable Group 3
22. Enable Group 4
23. Enable All Groups
24.
Reserved
s
Programming Functions (cont'd)
12
will clear all of the following: All Schedule Functions 72 through 93, Timeout Functions
l^ra 1^11^2
l^ra 1^0 1^0 1^01^:
l^q
1^3
l^q 1^01^01^0 ^ :
The Priority Order details which Function will
take effect before ("have priority over") others.
For example, as per the list above, Enabled
Users have the lowest priority, and other Func­
tions can affect the status of these Users. Dis­
abling a Group (Functions 14-18) will take pri­
0
d
2
:
ority over the enabled Users in that Group,
disabling them.
19-23) will take priority over those tasks lower
d
2
1
:
in the list, and finally disabling a User (Function
3) takes priority over all other tasks listed.
d
2
2
:
d
2
3
:
3
3
PRIORITY ORDER
1. Disabled Users
2. Enabled Groups
3. Disabled Groups
4. Enabled Users
Enabling Groups (Functions
17