Trilogy DL4100 Series Locks
"Privacy Terminated on Exit Only"
Function 68 has been enhanced to allow for an indefinite
Privacy Time-Out Duration.
; 6 8 ; [ _ _ _ ] :

ORIGINAL FUNCTIONALITY:

Specify Privacy Time-Out Duration
The Privacy Function is enabled by programming Function 67,
Option 35. In addition, Function 68 is normally used to specify
the Privacy Time-Out Duration (in minutes) by entering a num-
ber between 001-250 (be sure to enter 3 digits).
Privacy Time-Out Duration is the maximum time the lock will
remain in Privacy Mode, before returning to standard operation
(factory default time is 10 minutes).

ENHANCED FUNCTIONALITY:

Privacy Terminated on Exit Only (No Timeout)
Enter 251 to disable the Privacy Time-Out Duration: Privacy will
last indefinitely until either the inside lever is turned or until a
Master or valid Manager User Code is entered at the keypad. In
addition, the flashing LED is disabled.
© ALARM LOCK 2004
ADDENDUM
(3-digits)