Dmx Controller - ACME CM-150 PAGEANT 150 User Manual

Table of Contents

Advertisement

Stand By
Blackout the unit
Function
1. Sync. Strobe
2. Async strobe
3. Sound Strobe
Mode
Sound
(LED OFF)

4.3 DMX Controller

By using a universal DMX controller to control the units, you will need to set DMX address from 1 to 512
so that the units can receive DMX signal.
Press the MENU button up to when the DMX Address is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to change the DMX512 address. Once the
address has been selected, press the ENTER button to setup, to go back to the functions without any
change press the MENU button again. Hold and press the MENU button about one second or wait for
one minute to exit the menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units:
Channel mode
1channel
9channels
12channels
14channels
16channels
28channels
Show
1-4
Show
(LED Slow
Blinking)
Unit 1
Unit 2
Address
Address
1
2
1
10
1
13
1
15
1
17
1
29
1. Pan index
2. Tilt index
3. Dimmer
Show
(LED Fast
Blinking)
Unit 3
Address
3
19
25
29
33
57
12A
Fade Speed
1. Fast
2. Middle
3. Slow
LED ON
Unit 4
Address
4
28
37
43
49
85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Led-mb200r

Table of Contents