PLAN OF INSTALLATION – DETAILS
PLAN OF INSTALLATION – DETAILS

Concrete Pad

20"
Operator Cover
Operator Chassis
20"
See Note 1
Below
1. Follow the local building code to determine the required depth of the concrete pad.
2. Pad measurements recommended by Viking Access Systems are at lease 20" long,
20" wide and 30" deep to ensure the stable operation of the operator, and a
minimum of 6" above level grade to avoid any flooding of the machinery.
4. Provide a sufficient number of conduit pathways for all low power accessories
such as loop detector leads, maglock, non-contact sensors, contact sensors, safety
and other commands.Also provide conduit for the power supply (either 110 or
220 VAC). Extend the conduit the recommended height of 1" above the level of
the concrete pad. Install all conduit in the shaded area shown above.
Arm Assembly
Viking Access Systems can supply an Elbow Arm
Secondary Extension to make the F-1 unit back-
drivable. Contact Viking Access for availability.
Pivot Bracket
TECHNICAL SUPPORT 1 800 908 0884
Recommended Area
Gate Operator
Concrete Pad
Drill for a 1/2" x 3-1/2"
20"
Red Head Anchor
(4) Places
6" Minimum
Grade Level
See Note 2
Gate Operator Concrete Pad
Dimension E
on Page 10
Secondary Extension
for Conduit(s)
Conduit Location
Dimension
on Page 10
Primary Extension
2.5"
9.5"
2.5"
13"
D – 2.5"
11