Limit Switch Connections - Viking R-6 Installation Instructions And Use & Care Manual

Vehicular gate operator
Table of Contents

Advertisement

LIMIT SWITCH SET-UP
LIMIT SWITCH SET-UP
Opening/Closing Setup
1. Setup the limit switches manually at the desired open and close position.
2. Allow the gate operator to run a full open and close cycle (from limit to limit)
without interruption.
Note: During the first full open and close cycle: The gate operator doesn't slow
down prior to reaching its limits. During subsequent cycles: The gate operator will
slow down prior to reaching its limits.
3. Verify that the gate opens and closes to the desired position.
To change the open or close limit position(s) the following
steps MUST BE taken:
A. Reset the gate operator by actuating both limit
switches at the same time
B. Repeat steps 1,2 and 3.

Limit Switch Connections

The Limit Switches are wired as shown
Red
Black
Left Limit Switch
TECHNICAL SUPPORT 1 800 908 0884
White
Green
Slow
Fast
Slow
Cam
Right Limit Switch
Cam Wheel
17