Morso 2B Standard Installation And Operating Instructions Manual page 14

For use in north america
Table of Contents

Advertisement

The maximum recommended weight of wood fuel per load is 2.5 kg/h/5.5Ibs (approx 3 split
logs).
Under normal firing, the average flue temperature in the stove pipe, measured 20 cm above
the stove, is approx. 300° C (550°F). The maximum flue temperature in the stove pipe must not
exceed 450° C (750°F). If the flue temperature exceeds 450°C (750°F), it is considered as over
firing and may cause premature wear and tear of the stove.
To help gauge the correct running temperature of your stove, we recommend you use the Morsø
Flue Gas Thermometer (part # 62901200). The Flue Gas Thermometer magnetically attaches
onto the stove pipe approx 20 cm (8") above the stove's top plate and measures the surface
temperature of the stove pipe. Please see your authorized Morsø Dealer for availability.
Draft conditions
If smoke or fumes come out of your stove when lightning up and reloading, or if the fire simply
will not respond, a poor draft is almost certainly to blame. (In a very few cases, there may be
insufficient fresh air getting into the room - see installation advice above). Take advice from your
stove supplier on how best to upgrade your flue system to improve draft.
Rules of woodburning
If you want less heat, put fewer logs on the stove and reduce the amount of air. It is still important
to maintain a good layer of embers.
Less heat - less wood - less air
Greater heat - more wood - more air
Soot deposits will settle on the glass if the stove is run too slowly or if your wood is
not well seasoned.
15
14