Power Requirements; Environmental Conditions - NCR 7167 Owner's Manual

Two-station pos printer
Hide thumbs Also See for 7167:
Table of Contents

Advertisement

7167 Owner's Manual
Slew Speed
Print Zone
Noise
Graphics (Optional)
Other
Paper Diameter
Paper Length
Paper Width
Paper Thickness
Printable Area

Power Requirements

The 7167 printer receives power from a separate power supply. Here are the voltage
requirements for the power supply.
Voltage
24.0 V ± 10%

Environmental Conditions

Operating Temperature
Operating Humidity
Condensation may occur when equipment is transferred from cold to
warm areas after shipment. The printer's design permits operation after
drying out and stabilizing at room temperature.
254
Thermal Receipt Station
6.7 Inches per Second
2.83 Inches Maximum
57 dBA Sound Pressure (ISO 7779)
User-Defined Graphics, Logo
No Reverse Paper Feed
Thermal Receipt Station
80 mm Max.
83 Meters (273 feet)
80 mm ± 1mm
(3.15 Inches ± .02 Inches)
Not Applicable
2.83 Inches (Max.)
Station
Slip
Receipt
5°C to 45°C (40°F to 112°F), models with knife
5°C to 50°C (40°F to 120°F), models with no knife
5% to 90%
Slip Station
4.0 lines per Second
3.23 Inches Maximum
62 dBA Sound Pressure (ISO 7779)
User-Defined Graphics
Reverse Paper Feed
Two Form in Sensors
Impact Slip Station
Not Applicable
Side Insertion: 2.0 Inches (Min.)
Front Insertion: 2.75 Inches (Min.)
Side Insertion: 8.0 Inches (Min.)
Front Insertion: 2.0 Inches (Min.)
.406 mm (.016 Inch)
3.22 Inches (Max.)
Maximum Current
Short Term
Long Term
4.6 Amps
3.15 Amps
6.5 Amps
3.15 Amps