Carrier 48PG03-16 Controls, Start-Up, Operation, Service And Troubleshooting Instructions page 6

Single package small rooftop units with comfort link controls and puron (r---410a) refrigerant
Hide thumbs Also See for 48PG03-16:
Table of Contents

Advertisement

RUN
SERVICE
TEMPERATURES PRESSURES SETPOINTS
STATUS
TEST
Auto View of
Service Test
Run Status
Mode
Temperatures
(VIEW)
(TEST)
Software
Test Independent
Refrigerant
Version
Outputs
Temperatures
Numbers
(INDP)
(VERS)
(VERS)
Test Fans
Component
(FANS)
Run Hours
Test Cooling
Test Cooling
(HRS)
(HRS)
(COOL)
Component
Test Humidimizer
Starts
(HMZR)
(HMZR)
(STRT)
(STRT)
Test Heating
Control
(HEAT)
Modes
(MODE)
(MODE)
Cooling
Status
(COOL)
(COOL)
Heating
Status
(HEAT)
(HEAT)
Economizer
Status
(ECON)
(ECON)
5. Turn on field-supplied manual gas stop. Enter Service Test
mode by setting Service Test→TEST to "ON" using the
Scrolling Marquee display. Temporarily install the jumper
wire between "R" and "W1" on TB1. Use the Service Test
feature to set Service Test→HEAT→HT.1 to ON (first
stage of heat) using the Scrolling Marquee.
NOTE: Supply gas pressure must not exceed 13.0 in. wg.
6. Set Service Test→HEAT→HT.1 to OFF using Scrolling
Marquee.
Table 2—Scrolling Marquee Menu Display Structure
Occupied
Air
Suction
Pressure A
Cool Setpoint
(OCSP)
(AIR.T)
(SSP .A)
Unoccupied
Condenser
Cool Setpoint
Pressure A
(UCSP)
(REF.T)
(SCP .A)
Occupied
Suction
Pressure B
Heat
Setpoint
(SSP .B)
(OHSP)
(OHSP)
Condenser
Unoccupied
Pressure B
Heat Setpoint
(SCP .B)
(UHSP)
(UHSP)
Suction
Heat-Cool
Pressure C
(SSP .C)
Setpoint
(GAP)
(GAP)
Condenser
SPT Offset
Pressure C
Range (±)
(SCP .C)
(STO.R)
(STO.R)
Space RH
Setpoint
(RH.SP)
(RH.SP)
Space RH
Deadband
(RH.DB)
(RH.DB)
Reheat Heat
SP Deadband
(RH.HB)
(RH.HB)
Circuit A
Lockout Temp
(CA.LO)
(CA.LO)
Circuit B
Lockout Temp
(CB.LO)
(CB.LO)
Circuit C
Lockout Temp
(CC.LO)
(CC.LO)
Heating
Lockout Temp
(HT.LO)
(HT.LO)
Econo Cool
Hi
Temp Limit
Temp Limit
(EH.LO)
Econo Cool
Lo
Lo
Temp Limit
(EL.LO)
Free Cool
Free Cool
Low
Temp Limit
(FC.LO)
Low Cool SAT
Set Point
(LCSP)
High Cool
SAT
Set Point
(HCSP)
(HCSP)
Minimum SAT
Upper Level
(SAT.U)
(SAT.U)
Minimum SAT
Lower Level
(SAT.L)
INPUTS
OUTPUTS CONFIGURATION
Thermostat
Fan
Inputs
Outputs
(STAT)
(FANS)
General In-
Cool
puts
Outputs
(GEN.I)
(COOL)
Current
Heat
Sensor Inputs
Outputs
(CS.IN)
(HEAT)
Air Quality
Economiz-
Inputs
er
(AIR.Q)
Outputs
(ECON)
(ECON)
Alarm
Relay
(ALRM)
(ALRM)
↓ ↓
↓ ↓
7. Remove jumper wire if the unit will be operating under
thermostat mode. The jumper must remain if a space
temperature sensor (T-55, T-56, T-58, or System Pilot™
device) will control the unit.
8. Exit Service Test mode by setting Service Test→TEST to
"OFF" using the Scrolling Marquee.
6
OPERATI
TIME
NG
CLOCK
MODES
Time of Day
Display
Control
Configuration
(TIME)
Modes
(DISP)
(MODE)
Month, Date
Month, Date
Day and
Unit
Cool Mode
Year
Configuration
Diagnostic
(DATE)
(UNIT)
(COOL)
Daylight
Cooling
Heat Mode
Configuration
Savings
Diagnostic
Time
(COOL)
(HEAT)
(DST)
(DST)
Humidimizer
Economizer
Local Time
Config.
Diagnostic
Schedule
(HMZR)
(ECON)
(SCH.L)
(SCH.L)
Heating
Local
Configuration
(HEAT)
Holiday
Schedules
Schedules
Economizer
(HOL.L)
Configuration
(ECON)
Air Quality
Cfg.
(AIR.Q)
Alarm Relay
Config.
(ALM.O)
Sensor
Calibration
(TRIM)
CCN
Configuration
(CCN)
ALARMS
Reset All
Current
Alarms
(R CURR)
(R.CURR)
Reset
Alarm
History
History
(R.HIST)
Currently
Active
Active
Alarms
(CURR)
Alarm
Alarm
HIstory
(HIST)