AIRFLOW
AIRFLOW
0.2
(Cfm)
(Cfm)
Rpm
2550
446
2700
464
2850
481
3000
499
3150
517
3300
535
3450
553
3600
571
3750
590
3900
608
4050
627
4200
646
AIRFLOW
AIRFLOW
1.2
(Cfm)
(Cfm)
Rpm
2550
774
2700
781
2850
789
3000
798
3150
808
3300
818
3450
829
3600
840
3750
852
3900
864
4050
877
4200
890
LEGEND
Bhp --- Brake Horsepower
__
High Range Motor/Drive Required
AIRFLOW
AIRFLOW
0.2
(Cfm)
(Cfm)
Rpm
3000
502
3200
525
3400
549
3600
573
3800
597
4000
621
4200
645
4400
669
4600
694
4800
719
5000
743
AIRFLOW
AIRFLOW
1.2
(Cfm)
(Cfm)
Rpm
3000
800
3200
813
3400
827
3600
841
3800
857
4000
873
4200
889
4400
907
4600
925
4800
943
5000
962
LEGEND
Bhp --- Brake Horsepower
High Range Motor/Drive Required
Table 49—Fan Performance — 48PGF09 Horizontal Units
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
Bhp
Rpm
Bhp
0.39
524
0.51
0.45
538
0.57
0.52
553
0.65
0.59
569
0.72
0.67
584
0.81
0.75
600
0.90
0.85
617
1.00
0.95
633
1.11
1.06
650
1.23
1.18
667
1.35
1.30
684
1.49
1.44
701
1.63
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
Bhp
Rpm
Bhp
1.04
829
1.18
1.12
834
1.27
1.21
841
1.37
1.31
849
1.47
1.42
857
1.58
1.53
866
1.70
1.65
876
1.83
1.78
886
1.96
1.92
897
2.11
2.07
908
2.26
2.23
920
2.42
2.40
933
2.60
Table 50—Fan Performance — 48PGD12 Horizontal Units
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
Bhp
Rpm
Bhp
0.60
571
0.73
0.70
592
0.85
0.82
613
0.97
0.95
634
1.11
1.10
656
1.27
1.26
678
1.44
1.43
700
1.62
1.62
723
1.83
1.83
745
2.04
2.06
768
2.28
2.30
791
2.53
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
Bhp
Rpm
Bhp
1.32
851
1.48
1.46
862
1.63
1.62
874
1.79
1.79
887
1.97
1.97
901
2.16
2.18
916
2.37
2.39
932
2.59
2.63
948
2.83
2.88
965
3.09
3.15
982
3.37
3.44
1000
3.67
0.6
0.8
Rpm
Bhp
Rpm
593
0.63
657
605
0.70
667
618
0.78
678
632
0.86
690
646
0.95
703
660
1.05
715
675
1.16
729
690
1.27
742
705
1.40
756
720
1.53
771
736
1.67
786
752
1.82
801
1.6
1.8
Rpm
Bhp
Rpm
881
1.33
930
885
1.43
934
891
1.53
939
897
1.64
944
905
1.75
951
913
1.88
958
921
2.01
965
931
2.15
974
941
2.30
983
951
2.46
993
962
2.62
1003
974
2.80
1013
NOTES:
1. Motor drive range is 568 to 771 rpm for low range motor/drive and 812 to 1015 rpm
for high range motor/drive. All other rpms require a field-supplied drive.
2. Maximum continuous bhp is 2.40 for low range motor/drive and 3.70 for high range
motor/drive.
3. See General Fan Performance Notes.
0.6
0.8
Rpm
Bhp
Rpm
634
0.87
693
652
0.99
709
671
1.13
726
691
1.28
743
711
1.44
762
731
1.62
781
752
1.81
800
772
2.02
819
794
2.25
839
815
2.50
860
837
2.76
880
1.6
1.8
Rpm
Bhp
Rpm
899
1.64
946
909
1.80
955
920
1.97
964
932
2.15
975
945
2.35
986
958
2.56
999
973
2.80
1013
988
3.04
1027
1004
3.31
1042
1020
3.59
NOTES:
1. Motor drive range is 690 to 893 rpm for low range motor/drive, 852 to 1055 rpm for
high range motor/drive. All other rpms require a field-supplied drive.
2. Maximum continuous bhp is 3.10 for low range motor/drive and 3.70 for high range
motor/drive.
3. See General Fan Performance Notes.
32
1.0
Bhp
Rpm
Bhp
0.76
717
0.89
0.83
726
0.97
0.92
735
1.06
1.01
746
1.16
1.10
756
1.26
1.21
768
1.37
1.32
780
1.48
1.44
792
1.61
1.57
805
1.74
1.71
819
1.89
1.85
832
2.04
2.01
846
2.20
2.0
Bhp
Rpm
Bhp
1.49
978
1.65
1.59
981
1.75
1.70
985
1.87
1.81
990
1.98
1.93
995
2.11
2.06
1001
2.24
2.19
1008
2.38
2.34
1016
2.53
2.49
1024
2.69
2.65
1033
2.86
2.83
1042
3.03
3.01
1052
3.22
1.0
Bhp
Rpm
Bhp
1.01
748
1.16
1.14
762
1.30
1.29
777
1.45
1.44
793
1.61
1.62
810
1.79
1.80
828
1.99
2.00
846
2.20
2.22
864
2.42
2.46
883
2.67
2.71
902
2.93
2.98
922
3.21
2.0
Bhp
Rpm
Bhp
1.82
992
1.99
1.98
999
2.16
2.15
1007
2.34
2.34
1017
2.53
2.55
1027
2.75
2.77
1039
2.97
3.00
1051
3.22
3.26
1065
3.48
3.53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50pg03-16

Table of Contents