Carrier 48PG03-16 Controls, Start-Up, Operation, Service And Troubleshooting Instructions page 40

Single package small rooftop units with comfort link controls and puron (r---410a) refrigerant
Hide thumbs Also See for 48PG03-16:
Table of Contents

Advertisement

AIRFLOW
AIRFLOW
0.2
(Cfm)
(Cfm)
Rpm
1200
492
1300
513
1400
534
1500
557
1600
580
1700
603
1800
627
1900
651
2000
675
AIRFLOW
AIRFLOW
1.2
(Cfm)
(Cfm)
Rpm
1200
950
1300
955
1400
962
1500
971
1600
981
1700
993
1800
1005
1900
1019
2000
1034
LEGEND
Bhp --- Brake Horsepower
High Range Motor/Drive Required
AIRFLOW
AIRFLOW
0.2
(Cfm)
(Cfm)
Rpm
1500
568
1600
592
1700
616
1800
641
1900
665
2000
690
2100
716
2200
742
2300
768
2400
794
2500
820
AIRFLOW
AIRFLOW
1.2
(Cfm)
(Cfm)
Rpm
1500
978
1600
989
1700
1001
1800
1015
1900
1029
2000
1045
2100
1061
2200
1078
2300
1096
2400
1115
2500
1134
LEGEND
Bhp --- Brake Horsepower
Table 61—Fan Performance — 50PG05 Vertical Units
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
Bhp
Rpm
Bhp
0.15
604
0.22
0.18
620
0.26
0.21
638
0.29
0.24
657
0.33
0.28
677
0.38
0.33
697
0.43
0.38
718
0.48
0.43
739
0.54
0.49
761
0.61
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
Bhp
Rpm
Bhp
0.58
1023
0.69
0.63
1027
0.74
0.68
1032
0.79
0.74
1039
0.85
0.80
1047
0.92
0.87
1057
0.99
0.94
1068
1.06
1.02
1080
1.14
1.10
1094
1.23
Table 62—Fan Performance — 50PG06 Vertical Units
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
Bhp
Rpm
Bhp
0.25
667
0.34
0.29
687
0.39
0.34
708
0.44
0.39
730
0.50
0.45
752
0.56
0.51
775
0.63
0.57
798
0.70
0.65
821
0.78
0.73
845
0.86
0.81
869
0.96
0.91
894
1.05
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
Bhp
Rpm
Bhp
0.75
1046
0.87
0.81
1055
0.93
0.88
1065
1.00
0.96
1077
1.08
1.04
1090
1.16
1.12
1104
1.26
1.21
1119
1.35
1.31
1135
1.45
1.42
1151
1.57
1.53
1169
1.68
1.65
1187
1.81
0.6
0.8
Rpm
Bhp
Rpm
701
0.31
790
714
0.34
800
729
0.38
812
745
0.43
825
762
0.48
839
779
0.53
855
798
0.59
871
817
0.65
889
837
0.72
907
1.6
1.8
Rpm
Bhp
Rpm
1092
0.79
1157
1094
0.85
1158
1098
0.91
1161
1103
0.97
1165
1110
1.04
1171
1118
1.11
1178
1128
1.19
1186
1139
1.28
1196
1151
1.37
1206
NOTES:
1. Motor drive range is 596 to 910 rpm for low range motor/drive and 828 to 1173 rpm
for high range motor/drive. All other rpms require a field-supplied drive.
2. Maximum continuous bhp is 0.85 for low range motor/drive and 1.60 (single phase)
and 2.40 (3 phase) for high range motor/drive.
3. See General Fan Performance Notes.
0.6
0.8
Rpm
Bhp
Rpm
753
0.44
833
771
0.49
848
789
0.54
864
809
0.61
881
829
0.67
900
850
0.75
918
871
0.82
938
892
0.91
958
915
1.00
979
937
1.10
1000
960
1.20
1021
1.6
1.8
Rpm
Bhp
Rpm
1110
0.98
1172
1117
1.05
1178
1126
1.13
1185
1136
1.21
1194
1148
1.30
1204
1161
1.39
1216
1174
1.49
1228
1189
1.60
1241
1204
1.71
1256
1221
1.84
1271
1238
1.97
1287
NOTES:
1. Motor drive range is 690 to 978 rpm for low range motor/drive and 929 to 1261 rpm
for high range motor/drive. All other rpms require a field-supplied drive.
2. Maximum continuous bhp is 0.85 (single phase) and 2.40 (3 phase) for low range
motor/drive and 1.60 (single phase) and 2.40 (3 phase) for high range motor/drive.
3. See General Fan Performance Notes.
40
1.0
Bhp
Rpm
Bhp
0.39
873
0.49
0.43
880
0.53
0.48
889
0.58
0.53
900
0.63
0.58
912
0.69
0.64
926
0.75
0.70
940
0.82
0.77
956
0.89
0.85
972
0.97
2.0
Bhp
Rpm
Bhp
0.90
1219
1.02
0.96
1220
1.08
1.03
1222
1.15
1.09
1225
1.22
1.17
1229
1.30
1.24
1235
1.38
1.33
1242
1.46
1.41
1251
1.56
1.51
1260
1.65
1.0
Bhp
Rpm
Bhp
0.54
908
0.64
0.59
920
0.70
0.65
934
0.76
0.72
950
0.83
0.79
966
0.91
0.87
983
0.99
0.95
1001
1.08
1.04
1020
1.18
1.14
1039
1.28
1.24
1059
1.38
1.35
1079
1.50
2.0
Bhp
Rpm
Bhp
1.11
1231
1.23
1.18
1236
1.31
1.26
1242
1.39
1.35
1250
1.48
1.44
1259
1.58
1.53
1269
1.68
1.64
1280
1.79
1.75
1293
1.90
1.87
1306
2.02
1.99
1320
2.15
2.13
1335
2.29

Hide quick links: