Carrier 48PG Series Installation, Start-Up And Service Instructions Manual
Carrier 48PG Series Installation, Start-Up And Service Instructions Manual

Carrier 48PG Series Installation, Start-Up And Service Instructions Manual

Single package rooftop units electric cooling/gas heating with puron (r-410a) refrigerant and electromechanical controls

Advertisement

Quick Links

48PG03-07
Single Package Rooftop
Units
Electric Cooling/Gas
Heating
with PURON®
(R-410A)
Refrigerant
and Electromechanical
Controls
Installation, Start-Up, and
Service Instructions
CONTENTS
Page
SAFETY
CONSIDERATIONS
.......................
1,2
INSTALLATION
...................................
2-19
Step 1 -- Plan for Unit Location
.....................
2
Step 2 -- Provide Unit Support
......................
2
ROOF CURB
ALTERNATE
UNIT SUPPORT
Step 3 -- Rig and Place Unit .........................
2
INSTALLATION
ONTO CURB
SLAB MOUNT (Horizontal
Units Only)
Step 4 -- Field Fabricate
Ductwork
..................
4
Step 5 -- Make Unit Duct Connections
..............
4
Step 6 -- Install
Flue Hood and Inlet Hood ...........
7
Step 7 -- Install
External
Trap
for Condensate
Drain ..............................
8
Step 8 -- Install
Gas Piping ..........................
9
Step 9 -- Make Electrical
Connections
..............
9
• FIELD POWER SUPPLY
FIELD CONTROL
WIRING
Step 10 -- Optional
EconoMi$er
IV .................
13
Step 11 -- Install All Accessories
...................
19
PR E-START-U P .....................................
20
START-UP
.......................................
20-36
SERVICE
........................................
37-45
Cleaning
............................................
37
Lubrication
.........................................
38
Evaporator
Fan Service
and Replacement
..........
39
Evaporator
Fan Performance
Adjustment
...........
39
Evaporator
Fan Belt Tension
Adjustment
...........
39
Condenser-Fan
Adjustment
........................
39
Verify Sensor
Performance
.........................
40
Economizer
Operation
During Power Failure .......
40
Evacuation
.........................................
40
Refrigerant
Charge
.................................
40
Gas Valve Adjustment
..............................
42
High Altitude
.......................................
42
LP (Liquid
Propane) Gas Use .......................
42
Main Burners
.......................................
42
Filter Drier ..........................................
43
Protective Devices ..................................
43
Relief Devices
......................................
43
Control
Circuit
24-V ................................
43
Replacement
Parts .................................
43
Diagnostic
LEDs ....................................
43
TROU BLESHOOTING
............................
46-49
Unit Troubleshooting
...............................
46
EconoMi$er
IV Troubleshooting
....................
48
Phase Loss Protection
.............................
49
UNIT START-UP CHECKLIST
.....................
CL-I
SAFETY
CONSIDERATIONS
Installation
and servicing of air-conditioning
equipment
can
be hazardous
due to system pressure and electtic_d components.
Only trained
and qu_dified service personnel
should
inst_dl,
repair, or service air-conditioning
equipment.
Untrained
personnel
can perform
the basic maintenance
functions of cleaning coils and filters and replacing
filters. All
other operations
should be performed
by trained service per-
sonnel. When working on air-conditioning
equipment,
observe
precautions
in the literature, tags and labels attached to the unit,
and other safety precautions
that may apply.
Follow
all safety
codes.
Wear safety
glasses
and work
gloves. Use quenching
cloth for unbrazing
operations.
Have
fire extinguishers
available for _dl brazing operations.
Before performing
service or maintenance
operations
on
unit, turn off main power switch to unit. Electrical
shock
could cause personal injury.
Puron (R-410A) refrigerant systems operate at higher pres-
sures than stan&trd R-22 systems. Do not use R-22 service
equipment or components on Puron refrigerant equipment.
If service equipment is not rated for Puron refrigerant,
equipment dmnage or personal injury may result.
1. [mproper
inst_dlation, adjustment,
alteration,
service,
or maintenance
can cause property &Lmage, personal
injury, or loss of life. Refer to the User's Information
Manual provided with this unit for mote details.
2. Do not store
or use gasoline
or other
flammable
vapors and liquids in the vicinity of this or any other
appliance.
What to do if you smell gas:
1. DO NOT try to light any appliance.
2. DO NOT
touch any electrical
switch,
or use any
phone in your building.
3. IMMEDIATELY
call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's
instructions.
4. If you cannot reach your gas supplier, c_dl the fire
department.
Disconnect
gas piping flom unit when pressure testing at
pressure
greater
than
0.5 psig.
Pressures
greater
than
0.5 psig will cause gas valve damage resulting in haztudous
condition.
[f gas valve is subjected to pressure greater than
0.5 psig, it must be replaced
before
use. When pressure
testing field-supplied
gas piping at pressures of 0.5 psig or
less, a unit connected
to such piping must be isolated by
closing the manual gas valve(s).
Manufacturer
reserves the right to discontinue, or change at any time, specifications
or designs without notice and without incurring obligations.
PC 111
Catalog No. 534-80209
Printed in U.S,A,
Form 48PG-8SI
Pg 1
8-05
Replaces:
New

Advertisement

loading
Need help?

Need help?

Do you have a question about the 48PG Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

48pg0348pg0448pg0548pg0648pg07